9. OPERATION OF THE DISPLAY
The control unit has a back-lit display enabling you to view and program the operating parameters of the automated
system. Furthermore, it always shows the state of the automated system during normal operation. The following table
shows all the indications on the display during normal operation:
Displayed value State of automated system / description
Automated system closed at rest
O P
Automated system opening or open
t c
Automated system on pause (only with the selected automatic re-closure)
C L
Automated system closing
r r
Motor heating: it is shown only during the heating phase (to activate the function, see next
paragraph)
A S
Assistance request: it is shown only if the relevant parameter was enabled and if the number
of set cycles has been reached.
10. OPERATIONAL PARAMETERS
The operational parameters and their programming are shown on the display of the control unit with two characters: a
letter, lower case or upper case, and a number. The letter indicates the operation of the parameter we are modifying,
whereas the number indicates the set value. For example, if we read A2 on the display, this means we are modifying
parameter A, operation with or without encoder and motor power, and that it is currently set on 2.
To access adjustment of operational parameters, at first start-up, make use of the following procedure:
Power up the system and check that all the LEDs in the control unit are in the situation indicated in paragraph 8.
Make sure that the display shows value , automated system at rest.
Press and hold down push-button P2 until the name of the first parameter appears on the display.
Press push-button P1 to modify the set value.
To move on to the next parameter, press push-button P2.
When 60 seconds have elapsed without any key being touched, the control unit automatically exits the adjustment
mode. You can manually exit the adjustment mode by scrolling all the parameters with key P2. When the displays
show value , you have returned to normal operation.
The following table summarises all settable parameters and the assignable values:
Display
Description
Parameter Value
Operation with encoder / motor power adjustment
A
0
Operation of control unit with encoder
1
Low motor power
2
3
4
5
6
7
8
9
High motor power
Encoder sensitivity adjustment: This parameter is used to manage motor power and the encoders obstacle detection
sensitivity. This parameter is active only if parameter A is set on 0.
b
1
Minimum motor power, high encoder sensitivity
2
Medium-low motor power / medium-high encoder sensitivity
3
Medium-high motor power / medium-low encoder sensitivity
4
High motor power, low encoder sensitivity