Do you have a question about the Getinge Arjohuntleigh Parker and is the answer not in the manual?
Product Type | Bathing System |
---|---|
Brand | Getinge Arjohuntleigh |
Model | Parker |
Power Supply | 230V, 50Hz |
Color | White |
External Length | 2100 mm |
External Width | 800 mm |
Maximum Bathing Water Capacity | 220 liters |
Operation | Electric |
Explanation of terms used in the Instructions for Use.
Assessment criteria for residents prior to using the bath.
Relief of pain and itching, aid in healing inflamed tissue.
Requirements for installation by trained personnel.
Preparation of the floor and walls before bath installation.
Steps to perform before the Parker bath is used for the first time.
Steps to perform before each use of the Parker bath.
Operation of the drain control knob for opening and closing.
How to start and stop filling the footwell or whole tub.
How to activate and use the auto fill function.
How the electronic scalding protection works and what to do.
How to use and release the emergency stop button.
Operation of the shower handle for water control.
How to lock and unlock bath functions.
How to lock and unlock the bath door.
How to use the Air Spa system for massage.
How to use the Sound & Vision system.
How to use the integrated disinfection unit.
How the battery back-up works during power failure.
Description and attachment of optional cushions and leg rest.
Steps to fill the footwell with water.
Positioning the patient and ensuring safe seating in the bath.
Procedure for showering the patient during the bath.
Steps to drain the bath and end the bathing procedure.
Procedure for disinfecting the bath after each patient use.
Steps for transferring a patient using a standing and raising aid.
Ensuring patient safety and securing the bath door.
Transferring the patient out of the bath after bathing.
Steps for transferring a patient using a ceiling lift.
Adjusting bath height, filling, and checking temperature.
Draining the bath and disinfecting after use.
Information on approved disinfectants and usage.
List of accessories required for cleaning and disinfection.
Precautions during installation to limit bacterial growth.
Daily use practices to prevent microbial formation.
Steps to remove visible residue from the bath.
Detailed steps for cleaning the bath and accessories.
Detailed steps for disinfecting the bath and accessories.
Steps to remove visible residue from the bath.
Detailed steps for cleaning the bath and accessories.
Detailed steps for disinfecting the bath and accessories.
Specific steps to disinfect the Air Spa system.
Steps for disinfection after the last bath of the day.
Steps for disinfecting the bath after each patient.
Additional steps for disinfecting the Air Spa system.
Steps for rinsing the bath and accessories with MultiClean.
Additional steps for rinsing the Air Spa system.
Steps for operating Air Spa system during rinse.
Steps for disinfection after the last bath of the day.
Maintenance tasks to be performed by caregivers.
Cleaning and disinfection tasks between patient use.
Weekly checks for exposed parts, accessories, hoses, and controls.
Checking the door and seal for proper function and condition.
Testing all functions of the bath.
Verifying the functionality of the emergency stop button.
Monthly cleaning of shower head and exercising thermostat mixer.
Checking and cleaning filters for water supply hoses.
Actions for when the hand control or panel buttons are not working.
Troubleshooting power, backlight, and battery issues.
Resolving issues with beeping sounds and lift-only movement.
Troubleshooting Air Spa system stops and slow water flow.
Resolving problems with disinfection and auto fill functions.
Troubleshooting issues with the Sound & Vision system.
General dimensions, weight, and operational limits.
Water consumption, filling, and content specifications.
Specifications for the bath's thermometer.
Specifications for bath motion and sound levels.
Battery type and IP protection class specifications.
Weight information and recycling guidelines.
Compatible ArjoHuntleigh products for integration.
Requirements for site preparation and installation.
Specifications for floor load capacity and pressure.
Ambient temperature, humidity, and pressure for operation and storage.
Electrical specifications for different regions.
Information on the mains disconnection device.
Drain requirements and water supply specifications.
Specifications for hot and cold water pressure and temperature.
Requirements for drinking water quality.
Explanation of various labels and their meanings.
Explanation of symbols used in the manual.
Diagram showing the location of various labels on the bath.
List of standards and certificates the product complies with.
Information on electromagnetic emissions and their impact.
Information on electromagnetic immunity and compliance levels.
Guidelines for separation distances from RF equipment.
Table of separation distances based on transmitter power.
Details of back support cushion accessories.
Details of head cushion accessories.
Details of leg rest accessories.
Information on contacting for disinfectant supplies.