-1-
Instruction Manual
GEYA ELECTRICAL CO.,LTD
Add:Wenzhou Brige Industrial Zone,Beibaixiang Town,
Yueqing,Zhejiang,China 325603
Mobile:0086-13567770207
E-mail:sale@cngeya.com
Web:www.geya.net
Voltage / Current Protector GPS8-05
General
Applications
-Overvoltage ,undervoltage and overcurrent protection for household
equipment.
Function Features
-Voltage / current monitoring and protection.
-Special metering chips are used to detect voltage, current, electricity, and power.
-Double bus wiring design stronger ability.
-Over / under voltage value and over-current value can be set.
-Self reset after fault.
-Digital display voltage, current value, fault status can be displayed by LED.
-1-MODULE,DIN rail mounting.
Model and connotation
Technical parameters
Rated operational current
OFF,230V~300V
45~65Hz
AC220V(L-N)
1%
Rated supply voltage
Rated supply frequency
Over voltage operation value
Over/under voltage action delay
Reset time
Power- up delay
Measurement error
-20 ~ +60
-35℃ ~ +75
Din rail EN/IEC 60715
IP40 for front panel/IP20 terminals
any
82 36 68mm× ×
Operating temperature
Storage temperature
Mounting/DIN rail
Protection degree
Operating position
Overvoltage cathegory
Pollution degree
Dimensions
Weight
135g
Burden
AC max.3VA
GPS8-05
Function
Over voltage, under voltage and over current
0.1s~10s
140V~210V,OFF
Under voltage operation value
Over current operation value
Over current action delay
Functions Diagram
TpPower- up delay(2~600s)
TrReset delay time(2~900s)
TuOver/under voltage fault action time(0.1~10s)
TcOvercurrent fault action time(2~600s)
U
LED:
<Tu
Tp
Tr
Tr
I
LED:
LED: >I
Tp
Tr
LED: >U
LED: <U
I
>
Panel Diagram
Power open and close
indicator
Over voltage indicator
Under voltage indicator
Over current indicator
Operating voltage value
Operating current value
32A ,40A,50A,63A,80AAC1
1~32A,40A ,50A,63A ,80A
1×10
1×10
Mechanical life
Electrical life(AC1)
4
GPS8
GPS8 Series
Design number
U:upper incoming line
D:lower incoming line
Incoming line mode
05
Tu Tu
<Tu
Tc
Operation voltage range
80V~400V(L-N)
2s~600s
2s~600s
2s~900s
Parameter setting
Parameter
Range Step value Factory settings
Over voltage value
OFF,230V~300V
275V1V
Under voltage value
140V~210V,OFF
175V1V
Over current value
OFF,1A~32/40/50/63A
32A/40/50/63A0.1A
Over current action delay
2s~600s 5s1s
Reset time
2s~900s 30s1s
Fault reset
ON-OFF ON
Power on delay time
2s~600s 5s1s
Over voltage recovery value
225V~295V 265V1V
Under voltage recovery value
145V~215V 180V1V
Voltage fault action time
0.1s~10s 0.5s0.1s
M
Press and hold the setting key for 3 seconds to enter the
setting. After modifying the setting, press and hold for 3
seconds to save the setting.
Used to increase the value when setting parameters.
1.Used to reduce the value when setting parameters.
2.After exiting the setting, it can be used to manually turn
on or off the load.
3.If the automatic fault reset function is turned off, this button
can be used for manual reset when the fault occurs.
G P S8- 05 6 3A
N
N
IN
>I
<U
>U
M
>I
<U
>U
M
NOTE:
In the power off state, press and hold , and then power on again
to restore the factory settings.
GPS3-05 63
A
LCD backlight time
10s~900s,ON
1s
60s
Question and Answer IconNeed help?

Do you have a question about the GEYA GPS8-05 and is the answer not in the manual?

Summary

General

Applications

Describes the primary use of the device for household equipment protection.

Function Features

Lists the key functionalities like voltage/current monitoring, special metering chips, and digital display.

Model and Connotation

Explains the naming convention and series design for the GPS8 protector.

Technical Parameters

Panel Diagram

Illustrates the device's front panel layout, including indicators and controls.

Functions Diagram

Depicts the operational logic and timing sequences of the device's protective functions.

Parameter Setting

Manual Control

Describes how to manually switch the load on or off using the power key.

Power-On and Reset Delay

Explains the countdown display during power-on and fault reset sequences.

Query Electricity and Power

Details how to view measured power consumption and accumulated electricity usage.

Dimensions

Overview

The GEYA GPS8-05 is a voltage and current protector designed for household equipment, offering comprehensive protection against overvoltage, undervoltage, and overcurrent conditions. It features voltage and current monitoring, utilizing special metering chips to detect voltage, current, electricity, and power. The device is built with a double bus wiring design for enhanced durability and reliability.

Function Description:

The GPS8-05 provides protection by allowing users to set specific overvoltage, undervoltage, and overcurrent values. When these set limits are exceeded, the device automatically triggers a protection mechanism. A key feature is its self-reset capability after a fault, ensuring continuous operation once the fault condition is cleared. The device incorporates a digital display that shows real-time voltage and current values, as well as fault statuses, indicated by LED indicators. It is designed for 1-MODULE, DIN rail mounting, making it suitable for integration into standard electrical panels.

Important Technical Specifications:

  • Rated Supply Voltage: AC220V (L-N)
  • Rated Supply Frequency: 45~65Hz
  • Operation Voltage Range: 80V~400V (L-N)
  • Rated Operational Current (AC1): Available in 32A, 40A, 50A, 63A, 80A
  • Burden: AC max. 3VA
  • Over Voltage Operation Value: Adjustable from OFF, 230V~300V
  • Under Voltage Operation Value: Adjustable from 140V~210V, OFF
  • Over/Under Voltage Action Delay: 0.1s~10s
  • Over Current Operation Value: Adjustable from OFF, 1A~32A/40A/50A/63A
  • Over Current Action Delay: 2s~600s
  • Power-up Delay: 2s~600s
  • Reset Time: 2s~900s
  • Measurement Error: ≤1%
  • Electrical Life (AC1): 1×10⁴ operations
  • Mechanical Life: 1×10⁶ operations
  • Operating Temperature: -20°C~+60°C
  • Storage Temperature: -35°C~+75°C
  • Mounting/DIN Rail: EN/IEC 60715
  • Protection Degree: IP40 for front panel/IP20 terminals
  • Overvoltage Category: III
  • Pollution Degree: 2
  • Dimensions: 82×36×68mm
  • Weight: 135g

Usage Features:

The device's panel diagram includes LED indicators for overvoltage (>U), undervoltage (<U), and overcurrent (>I), along with displays for operating voltage and current values. A power open and close indicator (M) is also present.

Parameter Setting:

To enter the parameter setting mode, press and hold the (M) key for 3 seconds. Once in setting mode, the (∧) and (∨) keys are used to increase or decrease values. Holding these keys allows for rapid adjustment. If no operation is performed for 60 seconds, the device will automatically exit the setting mode. Users can also press and hold the (M) key for 3 seconds at any time to exit and save the settings.

The following parameters can be configured:

  • Over voltage value: Range OFF, 230V~300V (Factory setting: 275V)
  • Over voltage recovery value: Range 225V~295V (Factory setting: 265V)
  • Under voltage value: Range 140V~210V, OFF (Factory setting: 175V)
  • Under voltage recovery value: Range 145V~215V (Factory setting: 180V)
  • Voltage fault action time (Tu): Range 0.1s~10s (Factory setting: 0.5s)
  • Over current value: Range OFF, 1A~32/40/50/63A (Factory setting: 32A/40A/50A/63A)
  • Over current action delay (Tc): Range 2s~600s (Factory setting: 5s)
  • Power on delay time (Tp): Range 2s~600s (Factory setting: 5s)
  • Reset time (Tr): Range 2s~900s (Factory setting: 30s)
  • Fault reset: ON-OFF (Factory setting: ON)
  • LCD backlight time: Range 10s~900s, ON (Factory setting: 60s)

Manual Operation:

Under normal operation, the load can be switched on or off manually by pressing the (∨) key for 0.5 seconds.

Power-on and Reset Delay:

During power-on or fault reset, the product will display a countdown based on the set delay time (Tp or Tr). The device will enter its running state once the countdown concludes.

Query Electricity and Power:

The device can display real-time power (in Watts) and total quantity of electricity consumed (in kWh).

Wiring Diagram:

The manual provides wiring diagrams for two models: GPS8-02U (upper incoming line) and GPS8-02D (lower incoming line), illustrating the connection points for Neutral (N) and Line (L) terminals.

Factory Settings Restoration:

In the power-off state, press and hold the (∧) and (∨) keys simultaneously, then power on the device to restore factory settings.

Maintenance Features:

  • Fault Reset: If the automatic fault reset function is turned off, the (∨) button can be used for manual reset when a fault occurs.
  • Safety during Maintenance: The manual explicitly states that this product does not have an isolation function. Therefore, users must disconnect the superior MCB (Miniature Circuit Breaker) during any maintenance procedures to ensure safety.
  • Electrical Waste Disposal: All electrical waste should be disposed of in compliance with current WEEE (Waste Electrical and Electronic Equipment) regulations.
  • Installation: The product must be installed by qualified electricians, and all electrical connections must comply with appropriate safety standards.

GEYA GPS8-05 Specifications