page 1 of 12‡ SIGNET 8850-2 Conductivity/Resistivity Transmitter
Conductivity/Resistivity
62.50 uS
25.0°C
Relay 1
Relay 2
ENTER
‡ SIGNET 8850-2 Conductivity/Resistivity Transmitter
ENGLISH
2. Specifications
General
Compatible electrodes: +GF+ SIGNET 3-28XX-1 Standard and
Certified (NIST) Series Conductivity/Resistivity Electrodes
Accuracy: ±2% of reading
Enclosure:
Rating: NEMA 4X/IP65 front
Case: PBT
Panel case gasket: Neoprene
Window: Polyurethane coated polycarbonate
Keypad: Sealed 4-key silicone rubber
Weight: Approx. 325g (12 oz.)
Display:
Alphanumeric 2 x 16 LCD
Contrast: User selected, 5 levels
Update rate: 1 second
Electrical
Power: 12 to 24 VDC ±10%, regulated, 290 mA max.
Sensor input range:
Conductance: 0.055 to 400,000 µS
Resistivity: 10 K to 18.2 M
TDS: 0.023 to 200,000 ppm
( Measurements from 10 M to 18 M (0.055 µS to 0.1 µS) must
be performed in solution temperatures from 20 °C to 100 °C. )
Temperature: PT 1000, -25 to 120°C (-13 to 248°F)
Current output:
4 to 20 mA, isolated, fully adjustable and reversible
Max loop impedance: 50 max. @ 12 V
325 max. @ 18 V
600 max. @ 24 V
Update rate: 0.5 seconds
Accuracy: ±0.03 mA @ 25°C, 24 V
Relay outputs (2 sets mechanical SPDT contacts):
Maximum voltage rating:
5 A @ 30 VDC, or 5 A @ 250 VAC, resistive load
Hi or Lo programmable with adjustable hysteresis
Pulse programmable (maximum 400 pulses/minute)
Environmental
Operating temperature: -10 to 70°C (14 to 158°F)
Storage temperature: -15 to 80°C (5 to 176°F)
Relative humidity: 0 to 95%, non-condensing
Maximum altitude: 2000 m (6562 ft)
Insulation category: II
Pollution degree: 2
Standards and Approvals
CSA, CE, UL listed
Immunity: EN50082-2
Emissions: EN55011
Safety: EN61010
Manufactured under ISO 9001 and ISO 14001
U.S.A. Patent # 5,708,363
3-8850.090-2
CAUTION!
Remove power to unit before wiring
input and output connections.
Follow instructions carefully to avoid
personal injury.
Contents
1. Installation
2. Specifications
3. Electrical Connections
4. Menu Functions
1. Installation
ProcessPro transmitters are available in two styles: panel mount and field mount. The panel mount is supplied with the necessary
hardware to install the transmitter. This manual includes complete panel mounting instructions.
Field mounting requires a separate mounting kit. The 3-8050 Universal kit enables the transmitter to be installed virtually
anywhere. Detailed instructions for field installation options are included with the 3-8050 Universal kit.
1.1 Panel Installation
1. The panel mount transmitter is designed for installation using a 1/4 DIN Punch. For manual panel cutout, an adhesive
template is provided as an installation guide. Recommended clearance on all sides between instruments is 1 inch.
2. Place gasket on instrument, and install in panel.
3. Slide mounting bracket over back of instrument until quick-clips snap into latches on side of instrument.
4. To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE.
Press quick-clips outward and remove.
SIDE VIEW
92 mm
(3.6 in.)
97 mm
(3.8 in.)
56 mm
(2.2 in.)
41 mm
(1.6 in.
)
Optional
Rear
Cover
Field Mount
Panel Mount
FRONT VIEW
96 mm
(3.8 in.)
96 mm
(3.8 in.)
quick-clips
gasket
panel
terminals
mounting
bracket
latch
O
u
t
p
u
t
-
O
u
t
p
u
t
+
S
y
s
t
e
m
P
w
r
L
o
o
p
-
S
y
s
t
e
m
P
w
r
L
o
o
p
+
2
1
4
3
S
e
n
s
r
G
n
d
(
S
H
I
E
L
D
)
S
e
n
s
r
I
N
(
R
E
D
)
S
e
n
s
r
V
+
(
B
L
A
C
K
)
7
6
5
SIDE VIEW
Field Mount &
Panel Mount
Panel Mount
Installation Detail
106 mm
(4.18 in.)
82 mm
(3.23 in.)
D-10/01 English
Question and Answer IconNeed help?

Do you have a question about the GF Signet 8850-2 and is the answer not in the manual?

GF Signet 8850-2 Specifications

General IconGeneral
BrandGF Signet
Model8850-2
CategoryTransmitter
LanguageEnglish