Description
The 8900 Multi-Parameter Controller takes the
concept of modularity to the extreme. Two
base units, one with back-lit LCD and the
other with vacuum fluorescent display can be
configured by the user in the field. Ultimate
flexibility is achieved via plug-in modules for
either two or four input channels, universal AC
line voltage or 12 to 24 VDC operation, up to
four analog outputs, and up to four relays. The
controller will support up to four additional
relays, for a total of eight, by way of external
System Features
a) 8900 Base Unit: Select back-lit LCD or
vacuum fluorescent display
b) I/O Module: Select 2 or 4 input channels
with or without analog outputs
c) Power Module: Select AC or DC operation
d) Relay Module (optional): Dry-contact or
solid state relays
e) Analog Output Module (optional): Active or
passive 4 to 20mA, or 0 to 5/10 VDC
f) Comm Module (optional): RS232 (pending)
Features
Modular configurability
Absolute input versatility
up to four channels
1/4 DIN enclosure
•S
3
L™ digital connectivity
for pH, ORP, conductivity,
level, temperature and
pressure
Frequency input for
many flow sensor
options
Derived measurements:
Difference, Sum, Ratio,
% Recovery, % Rejection,
% Passage
Up to four analog
outputs
Up to eight relays
RS232 output (pending)
Display options
Plug-in terminals
Multi-language display
(pending)
Applications
RO/DI System Control
Media Filtration
Pure Water Production
Demineralizers
Chemical Processing
Metal & Plastics Finishing
Fume Scrubbers
Proportional Chemical
Addition
Cooling Tower & Boiler
Protection
Wastewater Treatment
Aquatic Animal Life
Support Systems
OUT 2 OUT 1
POWER
COMM PORT /
OUT 4 OUT 3
RELAY 2 RELAY 1
RELAY 4 RELAY 3
SENSOR INPUTS
a
b
d
e
f
c
8900
515
2210
525
2222
2536
2850
2540
7000
2541
2000
2350
2507
2550
2100
2450
2517
2750
7002
2750
Flow
Level
Temp.
Pressure
pH
ORP
Cond.
2450
Compatible Sensors
relay modules. Absolute input versatility
allows mixing and matching of up to four
sensors with S
3
L™ output including pH, ORP,
conductivity/resistivity, pressure, temperature,
and level. Two of the possible four input
channels may be used for any combination
of the many +GF+ SIGNET flow sensors with
frequency output. The table below indentifies
sensor models available for use with this
controller.
3-8900.099 (A - 2/03)

Other manuals for GF Signet 8900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GF Signet 8900 and is the answer not in the manual?

GF Signet 8900 Specifications

General IconGeneral
BrandGF Signet
Model8900
CategoryController
LanguageEnglish