Fusion process
Operating Instructions MSA 2
10
Next paragraphs describe step by step the interactions with the
electrofusion unit.
2.2 Switching On
Before connecting the machine to the power source, please read the
chapter 6 ‘Technical characteristics‘ and check the input voltage. If a
generator is used, this has to be started before connecting the electro-
fusion unit and must supply a constant output voltage! Any sudden
changes could compromise the correct welding result and/or damage
the control unit.
Connect the machine to the power mains or generator when the
generator is already started. At power on the display shows the
machine information: machine type, software version and serial
number.
2.3 Connect fitting
The next step consists of connecting the fitting to the machine by
the operator. The MSA 2.0 asks this with a prolonged sound.
The LED of the barcode scanner blinks to inform the operator it
has to do it.
Awaiting for that, the display shows the icon of a fitting and the
information about ambient temperature and current date/time.
Vo= --.-V
R = --.--
Ω
12/06/12 15:50 25°C
Attention
V 2.06
S156A6308001