Operating Instructions MSA 2 Technical characteristics
21
6 Technical characteristics
Mains voltage and frequency
230 V (265V÷190V) 40÷70 Hz
Suggested power generators
3.5kVA
Welding technique
Voltage controlled
Fusion voltage
42V (48 V)
Operating temperature
- 20 °C / +50°C
In
ternal temperature
- 20°C / +70°C
Temperature sensor resolution
± 1°C
Fittings range
Ø20mm ÷ 1200mm
(others on request)
Fusion data input mode
Bar code, manual
Capacity of internal memory
350 protocols (500 for MSA
2.1)
USB Port
Type A
Protection fa
ctor
IP 65
Dimensions
280x280x420 mm (max)
11,9 kg
6.1 Standards
ISO 12176-2
ISO 12176-3 (MSA 2.1 only)
ISO 13950
EN 60335 (Safety)
EN 61000-6-2/4 (EMC)

Table of Contents