EasyManua.ls Logo

GHP Group RA18LPDG - User Manual

GHP Group RA18LPDG
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
or email us at customerservice@ghpgroupinc.com
USER’S MANUAL AND OPERATING INSTRUCTIONS
MODEL # RA18LPDG, RA18LPDGD, RA18LPL
RA18LPDGP, RA18LPA, RA18LPB, and RA18LPC
PROPANE CONSTRUCTION HEATER
CONSUMER: Retain this manual for future reference.
IMPORTANT: READ AND UNDERSTAND
THIS MANUAL BEFORE ASSEMBLING,
STARTING OR SERVICING HEATER.
IMPROPER USE OF HEATER CAN
CAUSE SERIOUS INJURY. KEEP THIS
MANUAL FOR FUTURE REFERENCE.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE
PRECAUTIONS AND INSTRUCTIONS PROVIDED
WITH THIS HEATER, CAN RESULT IN DEATH,
SERIOUS BODILY INJURY AND PROPERTY
LOSS, OR DAMAGE FROM THE HAZARDS OF
FIRE, EXPLOSION, BURN. ASPHYXIATION,
CARBON MONOXIDE POISONING, AND/OR
ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND
FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER
INFORMATION SUCH AS AN INSTRUCTION
MANUAL, LABELS, ETCETERA, CONTACT THE
MANUFACTURER.
CALIFORNIA PROPOSITION 65: Fuels
used in gas or oil red appliances and
the products of combustion of such fuels,
contain chemicals known to the State of
California to cause cancer, birth defects
or other reproductive harm. This product
contains chemicals, including lead and
lead compounds, known to the State of
California to cause cancer, birth defects or
other reproductive harm. Wash hands after
handling.
Printed in China IMC18DG - GAX
C US
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.

Questions and Answers

  • R
    Renee GibsonAug 19, 2025
    What to do if I smell gas when GHP Group RA18LPDG is off?
    • R
      Rebecca Delgado MDAug 19, 2025
      If you smell gas even when the control knob of your GHP Group Gas Heater is in the OFF position, it could be due to gas leaks or a defective gas control. You should immediately locate and correct any leaks. Alternatively, the gas control may need to be replaced.
  • J
    Jacob WilliamsAug 21, 2025
    Why does the pilot light go out when I release the knob on my GHP Group Gas Heater?
    • A
      Alicia JohnsonAug 21, 2025
      If the ODS pilot light on your GHP Group Gas Heater lights but the flame goes out when you release the control knob, it could be due to several reasons. First, ensure you keep the control knob pressed in for about 30 seconds after the pilot lights. It's also possible the safety interlock has been triggered, so wait one minute and try the ignition operation again. Other potential causes include the pilot flame not touching the thermocouple, a damaged thermocouple, a loose thermocouple connection at the gas control valve, or a damaged gas control valve. In the case of a loose thermocouple connection, hand tighten until snug, then tighten 1/4 turn with a wrench. If the pilot flame is not touching the thermocouple, contact a qualified technician.
  • P
    Peter Taylor MDAug 25, 2025
    Why does my GHP Group RA18LPDG Gas Heater smell like gas when it's running?
    • G
      gwilliamsAug 25, 2025
      If you notice a gas odor during combustion in your GHP Group Gas Heater, it could be due to foreign matter in the gas or on the burner ports. Try checking the gas passageway and burner for any obstructions. It's also possible that the heater is burning vapors from paint or impurities in the air. In this case, ventilate the room and avoid storing or using odor-causing products near the heater. Another potential cause is gas leaks, so locate and correct any leaks immediately.
  • P
    Paula PenaAug 26, 2025
    Why won't the pilot light on my GHP Group Gas Heater light?
    • L
      lawrencegibsonAug 26, 2025
      If the pilot light of your GHP Group Gas Heater does not light when you press in the control knob, turn it counterclockwise to the pilot position, and depress the piezo, there might be a few reasons. Check if the gas supply is turned on and ensure the control knob is indeed in the pilot position and pressed in. There may also be air in the gas lines; purge them and repeat the ignition operation. If the ODS pilot is clogged, it is recommended to call a qualified service technician.
  • R
    Rebecca JosephAug 28, 2025
    Why does my GHP Group RA18LPDG Gas Heater keep shutting off?
    • N
      nsmithAug 28, 2025
      If your GHP Group Gas Heater shuts off on ODS (Oxygen Depletion Sensor), it may be due to insufficient fresh air. Try opening a window to increase ventilation. It could also be due to low gas pressure, in which case you should contact your gas supplier. Another possibility is that the ODS pilot is partially clogged, so try cleaning the pilot.
  • M
    Micheal BlairAug 30, 2025
    What to do if burner doesn't light on my GHP Group Gas Heater after pilot is lit?
    • D
      Dr. Chelsey DawsonAug 30, 2025
      If the burner on your GHP Group Gas Heater does not light after the ODS pilot is lit, the burner orifice might be clogged, and you should clean it. Alternatively, the gas supply pressure could be very low, and you should contact your gas supplier.
  • H
    Heather MirandaSep 1, 2025
    How to fix no spark at pilot light on GHP Group RA18LPDG?
    • S
      Steven SimmonsSep 1, 2025
      If there is no spark at the ODS pilot when the ignitor is depressed on your GHP Group Gas Heater, it could be due to several reasons. The ignitor electrode might be positioned incorrectly, so try repositioning it. The electrode could also be broken, in which case you should replace it. Another possibility is that the ignitor cable is pinched or broken; free the cable, and if it's damaged, replace it. Also, make sure the ignitor cable is connected to the ignitor electrode; if not, connect it. Finally, the ignitor itself might be defective, so consider replacing it.
  • H
    hallenSep 3, 2025
    Why is my GHP Group RA18LPDG backfiring?
    • D
      Darren AndersonSep 3, 2025
      If your GHP Group Gas Heater's burner is backfiring during operation, it could be because the burner orifice is clogged. Try cleaning the burner orifice. Alternatively, the burner ports might be damaged, requiring you to replace the burner.
  • E
    Edward MorrisSep 5, 2025
    Why does my GHP Group RA18LPDG Gas Heater have a delayed ignition?
    • S
      Stephen JonesSep 5, 2025
      If your GHP Group Gas Heater experiences delayed ignition, it could be due to clogged main burner carry over ports. Try cleaning the main burner ports. Alternatively, the gas supply pressure may be very low, in which case you should contact your gas supplier.
  • M
    Mr. Tommy Goodwin MDSep 7, 2025
    Why is my GHP Group RA18LPDG Gas Heater whistling?
    • L
      loriphillipsSep 7, 2025
      If your GHP Group Gas Heater produces a whistling noise when the burner is lit, it could be due to blocked air passageways. Check the minimum installation clearances and air passageways for any debris. It could also be due to air in the gas line. Operate the burner until the air is completely purged.

Summary

General Safety Information

Important Manual Reading

Emphasizes understanding the manual before operation to prevent injury or death.

Warning: Not For Use With Ductwork

States the heater is not designed for use with ductwork.

Critical Safety Instructions

Lists critical safety instructions like never leaving unattended.

General Safety Instructions

Propane Supply

Connecting to Gas Supply

Cylinder Compatibility

Stresses using only compatible LP cylinders with the supplied regulator assembly.

Propane Safety

Disconnected Tank Storage Prohibition

Prohibits storing disconnected propane tanks in enclosed areas.

Checking for Leaks

LP Gas Tank Purging and Filling Warning

Warns about the dangers of improper tank purging and filling.

Lighting Instructions

Shutdown Instructions

Storage

Maintenance

Warning: Blocked Air Openings

Warns about potential issues from blocked air openings.

Troubleshooting

Troubleshooting (continued)

Gas Odor When Off

Solutions for gas odor when the heater is off.

Gas Odor During Combustion

Addresses gas odor during the heater's operation.

Replacement Parts List

Residential Use Warning

States the heater is not for residential use.

Limited Warranty

Maintenance & Warranty Void

States that failure to perform maintenance voids the warranty.

Warranty Claim Procedure

GHP Group RA18LPDG Specifications

General IconGeneral
Fuel TypePropane
Heating Capacity18, 000 BTU
Ignition TypePiezo Ignition
Vent TypeVent-free
Oxygen Depletion Sensor (ODS)Yes
Safety Shut-offYes
Efficiency99.9%
TypePortable Gas Heater
Heating AreaUp to 700 sq ft
Mounting LocationWall or Floor (with optional legs)