20
Water Temperature Regulation
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly, and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting valves are
available.
Read instruction manual for safe
temperature setting.
'XHWRWKHQDWXUHRIWKHW\SLFDOJDVZDWHUKHDWHUWKH
ZDWHUWHPSHUDWXUHLQFHUWDLQVLWXDWLRQVPD\YDU\XSWR
&)KLJKHURUORZHUDWWKHSRLQWRIXVHVXFKDV
EDWKWXEVVKRZHUVVLQNHWF
HOTTER WATER CAN SCALD: Water heaters are
intended to produce hot water. Water heated to a
WHPSHUDWXUHZKLFKZLOOVDWLVI\VSDFHKHDWLQJFORWKHV
washing, dish washing, and other sanitizing needs can
VFDOGDQGSHUPDQHQWO\LQMXUH\RXXSRQFRQWDFW6RPH
SHRSOHDUHPRUHOLNHO\WREHSHUPDQHQWO\LQMXUHGE\KRW
ZDWHUWKDQRWKHUV7KHVHLQFOXGHWKHHOGHUO\FKLOGUHQ
WKHLQILUPRUSK\VLFDOO\PHQWDOO\KDQGLFDSSHG,IDQ\RQH
XVLQJKRWZDWHULQ\RXUKRPHILWVLQWRRQHRIWKHVHJURXSV
RULIWKHUHLVDORFDOFRGHRUSURYLQFLDOODZUHTXLULQJD
FHUWDLQWHPSHUDWXUHZDWHUDWWKHKRWZDWHUWDSWKHQ\RX
must take special precautions. In addition to using the
ORZHVWSRVVLEOHWHPSHUDWXUHVHWWLQJWKDWVDWLVILHV\RXUKRW
ZDWHUQHHGVDPHDQVVXFKDVDPL[LQJYDOYHVKRXOGEH
XVHGDWWKHKRWZDWHUWDSVXVHGE\WKHVHSHRSOHRUDWWKH
ZDWHUKHDWHU0L[LQJYDOYHVDUHDYDLODEOHIURPDSOXPELQJ
VXSSO\VWRUHVHH)LJXUH)ROORZPDQXIDFWXUHU¶V
LQVWUXFWLRQVIRULQVWDOODWLRQRIWKHYDOYHV%HIRUHFKDQJLQJ
WKHIDFWRU\VHWWLQJRQWKHWKHUPRVWDWVHH)LJXUH8VLQJ
WKHORZHVWKRWZDWHUWHPSHUDWXUHWKDWPHHWV\RXUQHHGV
ZLOODOVRSURYLGHWKHPRVWHQHUJ\HIILFLHQWRSHUDWLRQRIWKH
water heater.
1HYHUDOORZVPDOOFKLOGUHQWRXVHDKRWZDWHUWDSRU
WRGUDZWKHLURZQEDWKZDWHU1HYHUOHDYHDFKLOGRU
KDQGLFDSSHGSHUVRQXQDWWHQGHGLQDEDWKWXERUVKRZHU
NOTE:$ZDWHUWHPSHUDWXUHUDQJHRI&&
))LVUHFRPPHQGHGE\PRVWGLVKZDVKHU
manufacturers.
7KHWKHUPRVWDWRIWKLVZDWHUKHDWHUKDVEHHQIDFWRU\VHW
DWLWVORZHVWSRVLWLRQ,WLVDGMXVWDEOHDQGPXVWEHUHVHW
to the desired temperature setting to reduce the risk of
VFDOGLQMXU\7KH
PDUNLVLQGLFDWLYHRIDSSUR[LPDWHO\
&)DQGDUHWKHSUHIHUUHGVWDUWLQJSRLQWVVHH
)LJXUH6RPHSURYLQFHVKDYHDUHTXLUHPHQWIRUDORZHU
setting.
7XUQWKHZDWHUWHPSHUDWXUHGLDOFORFNZLVH WR
GHFUHDVHWKHWHPSHUDWXUHRUFRXQWHUFORFNZLVH
WR
increase the temperature.
6KRXOGRYHUKHDWLQJRFFXURUWKHJDVVXSSO\IDLOWRVKXWRII
WXUQRIIWKHPDQXDOJDVFRQWUROYDOYHWRWKHDSSOLDQFH
Checking the Draft
WARNING
Burn Hazard
Do not touch vent.
Doing so can result in burns.
$IWHUVXFFHVVIXOO\OLJKWLQJWKHZDWHUKHDWHUDOORZWKHXQLWWR
operate for 15 minutes and check the draft hood relief
RSHQLQJIRUSURSHUGUDIW)LJXUH0DNHVXUHDOORWKHU
appliances in the area are operating and all doors are closed
when performing the draft test. Pass a match flame around
WKHUHOLHIRSHQLQJRIWKHGUDIWKRRG$VWHDG\IODPHGUDZQ
into the opening indicates proper draft.
ATCH
RELIEF
OPENIN
DRAFT HOOD
FIGURE 17.
,IWKHIODPHIOXWWHUVRULVEORZQRXWFRPEXVWLRQSURGXFWVDUH
escaping from the relief opening. If this occurs, do not operate
the water heater until proper adjustments or repairs are made
WRWKHYHQWSLSHV\VWHPDQGRUDLUVXSSO\UHTXLUHPHQWV
Burner Flames
,QVSHFWWKHEXUQHUIODPHVWKURXJKWKHYLHZSRUWDQG
FRPSDUHWKHPWRWKHGUDZLQJVLQ)LJXUH$SURSHUO\
RSHUDWLQJEXUQHUVKRXOGSURGXFHDVRIWEOXHIODPH%OXH
WLSVZLWK\HOORZLQQHUFRQHVDUHVDWLVIDFWRU\7KHWLSVRI
WKHIODPHPD\KDYHDVOLJKW\HOORZWLQW7KHIODPHVKRXOG
QRWEHDOO\HOORZRUKDYHDVKDUSEOXHRUDQJHFRORur.
&RQWDPLQDWHGDLUPD\FDXVHDQRUDQJHFRORured flame.
&RQWDFWDTXDOLILHGVHUYLFHWHFKQLFLDQLIWKHIODPHLVQRW
VDWLVIDFWRU\
FIGURE 18.
Emergency Shut Down
,03257$176KRXOGRYHUKHDWLQJRFFXURUWKHJDVVXSSO\
IDLOVWRVKXWRIIWXUQRIIWKHZDWHUKHDWHU¶VPDQXDOJDV
FRQWUROYDOYHDQGFRQWDFWDTXDOLILHGVHUYLFHWHFKQLFLDQ