- 73 -
C-3.ConguringLegacyRAIDROM
Enter the Intel
®
legacyRAIDBIOSsetuputilitytocongureaRAIDarray.Skipthisstepandproceedwiththe
installationofWindowsoperatingsystemforanon-RAIDconguration.
Step 1:
In BIOS Setup, go to BIOS and set CSM Support to Enabled and Storage Boot Option Control to Legacy
Only. Save the changes and exit BIOS Setup. After the POST memory test begins and before the operating
systembootbegins,lookforamessagewhichsays"Press<Ctrl-I>toenterCongurationUtility"(Figure13).
Press<Ctrl>+<I>toentertheRAIDCongurationUtility.
Figure 13
Step 2:
After you press <Ctrl> + <I>, the MAIN MENU screen will appear (Figure 14).
Create RAID Volume
IfyouwanttocreateaRAIDarray,selectCreate RAID Volume in MAIN MENU and press <Enter>.
Figure 14
Intel(R) Rapid Storage Technology - Option ROM - 14.8.0.2377
Copyright (C) Intel Corporation. All Rights Reserved.
RAID Volumes :
None dened.
Physical Devices :
ID Device Model Serial # Size Type/Status(Vol ID)
1 Hitachi HDS72105 JP1532FR3BWV7K 465.7GB Non-RAID Disk
2 Hitachi HDS72105 JP1532ER046M2K 465.7GB Non-RAID Disk
Press <CTRL - I> to enter Conguration Utility...
Intel(R) Rapid Storage Technology - Option ROM - 14.8.0.2377
Copyright (C) Intel Corporation. All Rights Reserved.
4. Recovery Volume Options
5. Acceleration Options
6. Exit
RAID Volumes :
None dened.
Physical Deivces :
ID Device Model Serial # Size Type/Status(Vol ID)
1 Hitachi HDS72105 JP1532FR3BWV7K 465.7GB Non-RAID Disk
2 Hitachi HDS72105 JP1532ER046M2K 465.7GB Non-RAID Disk
[
hi
]-Select [ESC]-Exit [ENTER]-Select Menu
[ DISK/VOLUME INFORMATION ]
[ MAIN MENU ]
1. Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID