Installation instructions
Gira G1 temperature sensor module
2091 00
Gira
Giersiepen GmbH & Co. KG
Electrical installation
Systems
P.O. Box 1220
42461 Radevormwald
Tel +49 (0) 21 95 - 602 - 0
Fax +49 (0) 21 95 - 602 - 191
www.gira.de
info@gira.de
Security instructions
Device description
The Gira G1 temperature sensor module is an
additional device for the Gira G1. It serves to
measure the room temperature. The Gira G1
temperature sensor module is only suitable
for use indoors.
Fig. 1: Structure of Gira G1 temperature sen-
sor module
(1) Holding frame of Gira G1
(2) 6-pole spring contact
(3) Measuring element
Mounting the module
Selecting installation site
At an incorrectly selected installation site, the
Gira G1 temperature sensor module will
measure the room temperature incorrectly.
- Avoid an installation site that has a draught
(e. g. between a window and a door).
- Avoid direct proximity with heaters and
windows.
- Never cover the Gira G1 temperature sen-
sor module (e.g. curtain).
Unlocking and opening the Gira G1
Fig. 2: Unlocking Display module
1 Guide unlocking tool or thin screwdriver
into the unlocking opening (4) using slight
pressure.
The Display module is unlocked.
Fig.3: Removing Display module
2 Pull Display module forward on the top
side using force (5).
3 Remove Gira G1 (6).
Inserting temperature sensor module
Fig. 4: Inserting temperature sensor module
4 Remove blind plug to the left under the
holding frame.
5 Attach temperature sensor module with
the 6-pole spring contact at the former
position of the blind plug in the holding
frame. The 6-pole spring contact must be
visible in the process.
Swivelling in the Display module
Fig. 5: Swivelling in the Display module
6 Insert Display module in the guide element
of the holding frame (7).
7 Swivel Display module above (8).
The Display module engages with the
snap-in points and the holding frame.
Electrical devices may only be
installed by a qualified electrician.
i
Temperature detection via the
temperature sensor module is
only supported in the Gira G1
from index status I09.
(2)
(1)
(3)
(4)
(5) (6)
i
The Gira G1 has not correctly
engaged until the latch in the
unlocking opening has fallen
back into its end position.
(7)
(8)
43/17 10 86 19 80
GB

Other manuals for Gira G1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gira G1 and is the answer not in the manual?

Gira G1 Specifications

General IconGeneral
Resolution480 x 800 pixels
Power Supply24 V DC
Protection classIP20
DisplayTFT colour display
ConnectivityEthernet 10/100
MountingFlush mounting