1
Wall Mounted Water Bottle Refilling Station
070121
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
Servicio de atención al Cliente
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
WARNING
Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
For indoor commercial use only.
All installation work must be performed by authorized
service personnel.
Two or more people are recommended to lift and install
the unit.
To avoid the risk of property damage and/or personal
injury, mount the unit to a at nished wall surface with
adequate support.
Check local codes for plumbing requirements prior
to installation.
Prior to initial installation, install a shut-o valve (not
included) from the water supply.
Thoroughly ush all water lines and ttings of all foreign
matter before connecting to the cooler. Failure to do so
will void warranty.
Check for any leaks before initial operation.
DO NOT attempt to repair or replace any part of your
appliance unless it is specically recommended in
this manual. All other services should be referred to a
qualied technician.
For use with clean, clear potable drinking water only.
Shut-o water supply during installation to reduce risk
of water damage.
Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side
of
the cooler, as specied in rough-in guide.
NEVER wire the compressor directly to an electrical supply.
DO NOT allow children to play with the appliance.
Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
Failure to follow installation instructions will void warranty.
Note: These xtures are intended for indoor commercial
use only. Do not expose to freezing temperatures.
The grounding of electrical equipment to water lines is
a common procedure. This grounding may be in the
building or occur away from the building. This grounding
can cause electric feedback into the water cooler
creating an electrolysis which creates a metallic taste or
causes the water metal content to increase. Connect to
water supply using non-conductive materials.
Model 761219
b82045fc-0b136962-90871f19-f891407c
TM
TM
Read this manual thoroughly prior to
installation, operation or maintenance.
Keep these instructions in a safe location
for future reference. For questions, visit
globalindustrial.com or contact Customer
Service at 1-800-645-2982.
System 761219 certified by IAPMO
R&T against to NSF/ANSI/CAN 372
for lead free compliance

Questions and Answers

Summary

General Safety Warnings

Installation and Operation Precautions

Key safety instructions for compressor, installation, and general use of the water refilling station.

Electrical Safety and Installation Guidelines

Risk of Electrical Shock

Essential precautions to prevent electrical hazards during operation and maintenance of the unit.

Installation and Operational Warnings

Critical warnings for installation, compressor, and general appliance use, including electrical requirements.

Assembly Instructions

Initial Component Preparation

Steps for removing the lower cover and mounting bracket as part of the assembly process.

Safety During Assembly

Important safety note regarding the need for two people during assembly and installation.

Attaching Mounting Brackets and Back Plate

Instructions for removing and attaching the top mounting bracket and back plate during assembly.

Gasket and Bottle Filler Attachment

Steps for correctly attaching the gasket and the bottle filler assembly.

Connecting Water Lines and Wires

Instructions for connecting water lines and wire connectors to the cooling system.

Attaching Stainless Steel Pan and Safety Caution

Steps to attach the stainless steel pan and a caution about wire management.

Final Back Plate Attachment and Wall Mounting

Attaching the back plate and mounting the unit to the wall using a stencil and anchors.

Lifting and Handling Precautions

Safety guidelines for lifting and handling the assembled unit, emphasizing two-person lift.

Water Connections and Filter Installation

Valve Control and Water Supply Connection

Instructions for controlling water valves and connecting the building's water supply.

Water Filter Installation and Leak Check

Steps for installing the water filter and performing necessary leak checks.

Initial Power-Up and Pre-operation Checks

Final checks, including water supply, leak checks, and power connection, with compressor resting note.

Final Assembly and Safety Checks

Filter Access Door and Cover Reattachment

Steps for removing the filter access door and reattaching the lower cover.

Reset Cable Connection and Readiness

Connecting the reset cable and confirming the unit is ready for use.

Maintenance Safety Precautions

Safety warnings regarding electrical shock and general precautions during maintenance.

Operation and Settings Adjustment

Initial Operation and Filter Monitor

Notes on initial water flow, operation, and the LCD display when the unit is first plugged in.

Adjusting Water Flow Pressure

Instructions on how to adjust the water flow pressure using the water control valve.

Water Temperature Adjustment

Guidance on how to adjust the water temperature by accessing the thermostat.

Installing and Replacing Water Filter

Steps for removing and installing a new water filter, including resetting the filter monitor.

Programming and Filter Status

Accessing Programming Buttons

How to access the programming buttons by opening the filter access door.

Resetting Filter Status

Procedure to reset the filter status, indicated by LCD display and filter status bar.

Selecting Filter Size

Guide to select the appropriate filter size option for the unit.

Resetting Bottle Counter

Steps to reset the bottle counter to zero using the programming buttons.

Maintenance and Troubleshooting

Filter Status Lights Interpretation

Explanation of the LED bar displays for different filter level percentages.

Maintenance Precautions

Essential safety and cleaning precautions for maintaining the water refilling station.

Troubleshooting Common Issues

Solutions for common problems such as water temperature, flow, noise, and dispensing.

Global Industrial 761219 Specifications

General IconGeneral
BrandGlobal Industrial
MPN761219
Product TypeWater System
Model Number761219
ManufacturerGlobal Industrial