1. Installation instructions
1.1 Installation location
When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one CO alarm
in your home, install the alarm near bedrooms, not in the basement or furnace room. The recommended position for the unit should
be at least 1.8 meters (about 6 feet) above the floor level.
CAUTION: This alarm should be installed by a competent person.
1.2 Mounting step
1: Drilling two ф5.0mm holes in the wall, the distance between two holes center is 52mm(2.0 inch),then inserting two plastic stopper
provided into the holes.
2: Insert the two screws provided until the screw heads are approximately 5mm from wall.
3: Test the unit by using the TEST/SILENCE button. Ensure the unit sound is alarm pattern.
4: Hook the unit over the screws onto keyholes in back of unit.
As you install the battery on the unit, maybe it will sound for several minutes, then stop and enter in normal operation mode.
If it always sounds, please call our agent.
1.3 Recommended installation locations:
The following suggestions are intended to help you with the placement and installation of your CO alarm.
■Place out of the reach of children. Under no circumstance should children be allowed to handle the CO alarm.
■ Install in a bedroom or hallway located close to the sleeping area. Take special care to verify the alarm can be heard in sleeping
areas.
■ It is recommended that a CO alarm be installed on each level of a multilevel home.
■ Locate 1~3 meter (3.3~10feet) away from all fuel burning appliances.
■ Placing at eye level allows for optimum monitoring of the red and green indicator lights.