110824
4.2 Technician level F:
To enter the technician level, in normal mode, first press the S button and then also press the P
button for 3 seconds until the display shows “F”.
Display will now show the technician level F.
Press P button to select a parameter in the technician level F:
M = synchronizer mode (0 = no synchro, 1 = synchro)
Z = speed level setting (see columns next page)
L = speed limit setting (see columns next page)
C = torque setting (1 = lowest, 9 = highest)
N = low speed setting (positioning speed, 0 = highest, 9 = lowest)
A = save parameter setting as factory setting, press S button for 3 seconds
until display shows “O” and then “K” (OK).
When the correct parameter is selected with the P button, press the S button to read the
current value of the parameter. Press the S button again to change the value of the selected
parameter. When the selected parameter is set to the correct value, press the P button to
confirm the value. Display will now
show “O” and then “K” (OK).
4.3 Parameter Reset:
In normal mode (P.) press the S button for 3 seconds until the display shows
“O” and then “K” (OK).
From the library of Superior Sewing Machine & Supply LLC - www.supsew.com