GlobalTestSupply Druck UPS-II User Manual

GlobalTestSupply Druck UPS-II
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GE
Sensing & Inspection Technologies
Druck UPS-II
Loop Calibrator
User manual - K0434
OUT
INT
OFF
LOOP
PWR
READ
EXT
UPS - II
mA
%
*
VALVE
LIN
FLO
W
%
M
A
STEPS
FIXED
loop calibrator
RANGES:
OUTPUT & REA
D 0 - 22.2 mA
PRES
S * 2 SEC.
TO DISPLAY MENU
SCROLL FUNCTIONS WITH KEY
PRESS *TO ENTER FUNCTION
PRESS *TO SELECT FIXED STEPS
USE OR TOADJUST OUTPUT
a
Druck
a
ADruckCompany
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Question and Answer IconNeed help?

Do you have a question about the GlobalTestSupply Druck UPS-II and is the answer not in the manual?

GlobalTestSupply Druck UPS-II Specifications

Power IconPower
internal loop power24 VDC stabilized
external loop power48 VDC max.
battery4 x 1.5V alkaline or rechargeable size AA
Operating Environment IconOperating Environment
operating temperature-10°C to 50°C
storage temperature-20°C to 60°C
temperature effect0, 003%/°C
Electrical Specifications IconElectrical Specifications
range0 to 22.2 mA
accuracy0, 05% of range
resolution10 microamps
Weight and Dimensions IconWeight and Dimensions
weight212 grams
size77 x 124 x 21 mm

Summary

Battery Safety

Introduction

Operation

Fixed Steps

To output fixed calibration currents in series using the device.

Valve mode

Details on stepping in valve mode and selecting start currents.

Ramp mode

How to output continuous up/down ramp cycles and select start direction.

Batteries

Replacement

Step-by-step instructions for replacing the instrument's batteries.

Technical Notes

Current reading

Diagram showing switch positions for current reading.

Transmitter Calibration

Diagram showing switch positions for transmitter calibration.

Transmitter Simulation

Diagram illustrating switch positions for transmitter simulation mode.

Valve Stroking

Diagram showing switch positions for valve stroking function.

Calibration Instructions

General

General calibration period, test equipment suitability, and environment.

Calibration Equipment

Accuracy requirements for calibration equipment and the UPS-II.

Calibration Check

Calibration Adjustment

Measure mode

Step-by-step instructions for calibrating the measure mode.

Source mode

Step-by-step instructions for calibrating the source mode.

Completion

Final steps after calibration, including equipment disconnection and record updates.

Specifications