15.14 Heating Flow Thermistor
For access, refer to section 15.1.
Refer to diagram 15.10.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the ow pipe.
NOTE: When reconnecting, the polarity of the wiring to
thermistors is not important.
15.15 Heating Return Thermistor
For access, refer to section 15.1.
Refer to diagram 15.10.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the return pipe.
NOTE: When reconnecting, the polarity of the wiring to
thermistors is not important.
15.16 Condense Drain
For access, refer to section 15.1.
Refer to diagram 15.11.
Remove the igniter unit as described in section 15.3 to
improve accessibility.
Remove the securing clip from the heat exchanger adapter,
then disconnect the adapter and exible hose.
Lift the siphon adapter and hose out of the condensate trap
and siphonic drain, do not disconnect the hose.
Disconnect the drain connection.
Slacken to disengage but do not remove the two securing
screws.
The condense trap will contain water, lift taking care not to
spill the water.
After replacement and before tting the adapter ll the trap
with water.
Cleaning
Remove the condense trap as previously described.
Remove the oat to clean it.
Remove any solids found.
Flush water through the trap to remove any remaining solids.
Check for any debris in the outlet hose of the condensate
drain and clean as necessary.
13544
15 Replacement of Parts
Diagram 15.11
Diagram 15.10
13316

Other manuals for Glow-worm 30cx

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm 30cx and is the answer not in the manual?

Glow-worm 30cx Specifications

General IconGeneral
Model30cx
CategoryBoiler
Output30 kW
Efficiency RatingA
ERP RatingA
Dimensions (H x W x D)740 x 418 x 300 mm
MountingWall Mounted
Fuel TypeNatural Gas
Domestic Hot Water Output (kW)30 kW
Central Heating Flow Temperature Range30-80°C
Gas TypeNatural Gas
Water Pressure0.5 - 3 bar
TypeCombination boiler

Related product manuals