Loading...
This is a modern room sealed instantaneous water heater designed to supply
hot water to several taps which may be situated. in different rooms.
The pilot is lit by a piezo spark igniter, no batteries or efectricity are
required. The main burners will automatically light when a hot water tap
is turned on and go out when the tap is turned off.
In your own interest and that of safety it is law that all gas appliances are
installed by competent persons in accordance with the above regulations.
Failure to instal1 appliances correctly could lead to prosecution.
SUMMER/
WINTER
CONTROL
HIGNITION
I
~GAS ON
.OFF
PILOT
VIEWING
WINDOW
ENSURE THAT ALL HOT WATER TAPS ARE TURNED OFF BEFORE
LIGHTING THE PILOT. IF PILOT BLOWS OUT WAIT THREE MINUTES
THEN CARRY OUT LIGHTING PROCEDURE AGAIN.
Ensure that the main gas supply is turned on. Turn off al1 HOT water
taps. Ful1y depress the 'gas on' button marked ~ <...ndpress and release
the spark ignIter button marked
H
until the pilot is lit. The pilot may be
observed through the pilot viewing window. Keep the 'gas on' button ful1y
depress'ed in for la seconds after the pilot has been lit and then release.
If the pilot goes out repeat the operation.
Once the pilot is alight the main burner will be lit by turning on any of
the hot water taps.
7105
All manuals and user guides at all-guides.com

Other manuals for Glow-worm ASCOT 1.4S

Related product manuals