EasyManua.ls Logo

Glow-worm Ultimate 70FF - Page 15

Glow-worm Ultimate 70FF
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
2000225233B
4 Flue and Appliance Preparation
Diagram 4.9
BOILER
CENTRE
LINE
LONG FLUE
TERMINAL
STANDARD
FLUE
TERMINAL
6830
4.10 Rear Fitting
Fit the self adhesive foam seal provided in the flue pack around
the air duct/terminal at the position shown in diagram 4.13.
4.11 Side Fitting
Fit the self adhesive foam seal around the air duct/terminal such
that, when installed, the seal will be within the wall, see diagram
4.14.
If dimension "A" is greater than 75mm from the wall, the self
adhesive foam seal can be dispensed with, and the area around
the flue made good in the normal way, see diagram 4.14.
Important: If the wall liner kit is used the self adhesive foam seal
included in the wall liner kit must be used in place of the one
supplied with the flue pack, see diagram 4.11 for position of self
adhesive seal.
Diagram 4.10
AIR DUCT/TERMINAL
AND FLUE DUCT
ASSEMBLY
4616

Related product manuals