Gobius Pro, Instructions on paper, August 2020-1
Gobius Sensor Technology AB
Ljungåsvägen 2
Phone +46 (0)31 650170
Halmstad www.gobius.se
Hi.
This information is for you who want them in writing and not just on your phone.
You will get the same and more updated info when downloading the App, Gobius,
from Internet, Google play and App Store.
Please note that you must get the App before installing the sensor. You do all
settings from the App.
If you connect a panel like our Gobius fish with 2 LEDs in red and green,
you do not need your phone to use the sensor.
1
Download the Gobius App from Google Play or App Store.
Note: The first time you start the App, you will get a question
“Gobius Pro would like to use Bluetooth”. Please answer Ok.
Never “Don’t Allow”.
2
In the Gobius Pro box you get:
- 1 sensor with 2 m cable
- 1 tank surface 3M Cleaner
- 1 extra 3M sensor tape
- 1 panel (the Gobius fish) with
1 red and 1 green LED light
3
Check the tank wall thickness. If it is thicker than the specification,
Gobius Pro will not work.
- Stainless Steel & Steel, max 3 mm
- Polyethelene, max 12 mm
- Aluminium, max 5 mm
- Fibre Glass, max 8 mm
4
There are some more important things you have to consider
before mounting the sensor on the tank wall.
- Do not put the sensor closer than 35 mm from an edge,
or another sensor and always on a vertical side of the
tank.
- The tank wall temperature must be above + 20 C (+ 68 F).
If it is below the tape will not work satisfying.