2
SAFETY PRECAUTIONS
- te with simplified installation (non-polarised 2 wire bus).T-ART lephone
- Up to 4 /monitors per apartment (master, slave 1, slave 2 and slave 3).T-ART
telephones
- Up to32 apartments/T-ART terminals in mixed installations with monitors .(EL632G2+ SE module)
- Up to 128 apartments/ terminals per installationT-ART (EL6 2 G2 sound module required).4 +
- Completely private conversation.
- Call reception volume control: min, med, max and off (do not disturb).
-Audio volume control during communication process (4 different levels).
- nput for calls from door."HZ" i apartment front
.
- Output to auxiliary call repeater (maximum 50mA/12Vdc).
- ifferent ringtones to identify the origin of the call (door panel, intercom orUp to 6 d , guard monitor
front door of the apartment).
- Button for lock release 1 activation. In standby : activate/ deactivate(handset on or off the hook)
"Doctor mode”.
- Button for lock release 2 activation/ staircase light activation (SAR-G2 SAR-12/24 modules+ &
required) / "intercom" calls (within the same apartment)and "autoswitch-on" function.
- Button for tone call volume control, "do not distrurb" mode/ configuring ringtones/ communication call
volume control (T-ART speaker) & in case ofcall forwarding, cancel call transfer (withART 7W monitor).
- Button for guardmonitor calls (if exist).
- DIP switches for setting the te 's address (call code), master/slave and end of line.lephone
-
Always disconnect the power supply before making modifications to the device.
- The fitting and handling of these devices must be carried out by .authorised personnel
- The wiring must run at least 40 cm away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the te in a dry protected location free from the risk of dripping or splashing water.T-ART lephone
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply and .T-ART telephones
- Always follow the instructions contained in this manual.
CHARACTERISTICS
SYSTEM OPERATION
- To make a call, the visitor needs to press the button for the apartment, an audible tone indicates
that the call is being made and LED on the door panel illuminates. If vocal synthesis is enabled,
a 'Call is in progress' message appears indicating that a call is being made. At this moment, the
apartment's te (s) receives the call. If another apartment is called by mistake, press thelephone
button for the correct apartment and the first call will be cancelled.
- Upon receiving the call, the telephone’s LED will blink white. If the call is not answered within 40
seconds, LED will turn offthe door panel’s , the telephone’s LED and
switch on (white color)
the channel will be freed.
- Door panel’sTo establish communication, on any te in the apartmentlift the handset lephone .
LED willwill turn off, the led turn on and the telephone’s LED .switch on (white color)
-
Communication will last for one and a half minutes or until . Whenthe handset is replaced
communication has finished, LED will turn off and the channel will be freed. If vocaldoor panel’s
synthesis is , a 'Communicationis finished' message will indicate that the call is over.enabled
- To open the door, press button (if it exists and, to open the second door, press button )
during the call or communication processes: one press activates the lock release for seconds3
and LED on the door panel will also illuminate for seconds. If vocal synthesis is enabled, a3
'Door en' message will be indicated on the door panel.is op
- Description of the function buttons can be found on p. 3.
*
( )
*
( )
3
DESCRIPTION OF THE TELEPHONE
*
( )
*
( )
Description of the DIP switch and conf guration of the terminal address (code):i T-ART/G2+
*
( )
Description:
ENEN
Building / Villa (Nexa Door Panel)
Dip1 Dip :- 7 Note:Sets the address (addresses to ).terminals 1 128 Mixed installations withmonitors (addresses 1 to 32).
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
terminal code is the sum of the values of the switches set to ON.
.
Dip -Dip :8 9 terminal only terminalThese define whether the is masteror slave. Eachapartment musthave one master .
.
Master Slave 1 Slave 2 Slave 3
Dip :10 Configures the end of line. In installations with terminals only, it must always be in the OFF position. In
mixed installations of monitors with te in the same apartment, set to ON for the teT-ART/G2+ lephones lephones
in which the BUS cable ends and leave in the OFF position for intermediate terminals.
.
IMPORTANT: T-ART/G2+ terminal in , see corresponding Kit Soul userVilla installation with SOUL door panel
manual for Kit features as maximum number of apartments and monitors/ T-ART/G2+ terminals.
Table of values
Important:
Apartment 1 (Dip1 to ON & Dip2-Dip7 to OFF).
Apartment 128 (Dip1-Dip7 to OFF).
1 2 3
ON
Example: 0+ 0+4+0+16 0+0+ = 20
Switch number: 1 2 3 4 5 6 7
Value when ON 1 2 4 8 16: 32 64
4 5 6 7 8 9 10
1 2 3
ON
4 5 6 7 8 9 10 1 2 3
ON
4 5 6 7 8 9 10 1 2 3
ON
4 5 6 7 8 9 10 1 2 3
ON
4 5 6 7 8 9 10
a.
b.
c.
d.
Handset.
Function push buttons.
Raised dots for the visually impaired people.
In call :/communication
Above these raised dots is the 'Door opening'
button.
Status LEDs.
Wall mounting connector fixing (x4).
Golmar use.
Configuration switches.
Bus connection terminals.
Label.
Apartment front door button input.
Auxiliary call repeateroutput (max. 50mA/12Vdc).
e.
f.
g.
h.
i.
j.
k.
Function push button:
During the call or communication processes: one press
will activate the lock release 1. In standby (handset
on or off the hook): press the button for 5 sec. to
activate/deactivate the "Doctor mode" function.
In standby (handset on the hook): short press, it allows
to change tone call volume, on every short press
te reproduces the selected volume (cyclic min/lephone
med/ max/ off "do not disturb"). onIn communication:
every short press, it allows to change the speaker of
the T-ART audio volume (cyclic 4 audio levels). Other
settings see"TT-ART/G2+" user manual.
- Led switch on (white color).In standby: During call door
panel, guard or intercom process:Led will blink (white color).
Terminal in communication: Led switch on (white color).
- : Led switch on (red color)."Do not disturb" mode To confirm
default tones& tones volume: Led blink9 times (red color).
- Led switch on (red"Automatic door opening" Doctor mode:
color).
HZ
Function push button status LED:
Description connection terminals:
During the call or communication processes: one press
will activate the lock release 2. In standby (handset on the
hook): press the button for 3 sec. to activate the staircase
light & modules required 5 short2+(SAR-G SAR-12/24 ).
press to default tones & tones volume (led blink 9
times). 2 short press toIn standby (handset off the hook):
"intercom" call (within the same apartment) press forand
3 seconds to "autoswitch-on" function.
*
( )
HZ
GND
SA
(Auxiliary call repeater
, max. 50mA/12Vdc).output
( .Door bell connection)
BUS (non-polarised)connection .
T- TELEPHONEART/G2+ T- TELEPHONEART/G2+
For more information, see T user manual (code 5012 )."T -ART/G2+" 2719
https://doc.golmar.es/search/manual/50122719
For more information, see T user manual (code 5012 )."T -ART/G2+" 2719
https://doc.golmar.es/search/manual/50122719
b
a
d
e
i
k
h
g
f
c
AUX
DIP 8,9
00 - Master
10 - Slave 1
OFF = 0 | ON = 1
01 - Slave 2
11 - Slave 3
DIP 1 to 7
Monitor address
DIP 10
End of line resistor
BUS HZ
GND
GOLMAR S.A. C/ Silici, 13. 08940-SPAIN
SA
e
j
In standby (handset off the hook): One short press for