Do you have a question about the Goodman ComfortNet ASZC160601CA and is the answer not in the manual?
Brand | Goodman |
---|---|
Model | ASZC160601CA |
Category | Heat Pump |
Cooling Capacity (BTU) | 60000 |
SEER | 16 |
HSPF | 9.5 |
Stages | 2 |
Voltage | 208/230 |
Refrigerant Type | R-410A |
Compressor Type | Scroll |
Phase | 1 |
Warranty | 10 years parts |
Explains how capacity control works in ComfortNet models via the unloader solenoid.
Describes the UC PCB, its functionality, and compatibility with HVAC systems.
Explains the defrost cycle control for ComfortNet models, including sensor and timing.
Provides a chart for diagnosing cooling and heat pump system problems.
Procedures for checking system voltage, wiring integrity, and ComfortNet thermostat.
Detailed steps for checking system voltage and wiring for proper function.
Covers advanced system features, diagnostics menus, and fault history access.
Guides on troubleshooting network issues using LEDs, charts, and diagnostic codes.
Details diagnostic codes for PCBJA101/PCBJA102 air handlers, including symptoms and corrective actions.
Details diagnostic codes for PCBJA104 air handlers, covering motor issues and airflow.
Details diagnostic codes related to motor operation, voltage, and parameter issues.
Details diagnostics for Copeland Comfort Alert on unitary controls for specific models.
Provides diagnostic codes for ComfortNet systems related to low side faults and LPCO lockouts.
Lists all unitary diagnostic codes indicated by 7-segment LED displays.
Covers diagnostic codes for high line voltage, low pilot voltage, and compressor protector open.
Covers safe checking of compressors, including resistance and ground tests.
Procedure to test the unloader function of the compressor using diagnostic controls.
Tests compressor operation and procedures for testing crankcase heaters and reversing valves.
Explains how to test temperature sensors for ComfortNet models.
Describes the electronic control for AVPTC/MBVC models, including its features and basic operation.
General guidelines and safety precautions for refrigeration system repairs.
Procedure for leak testing refrigeration systems using dry nitrogen and system evacuation.
Procedure for charging the refrigeration system with the correct amount of refrigerant.
Critical warnings and cautions about handling refrigerant under pressure and using certified refrigerant.
Procedures to check compressor efficiency, overfeeding, underfeeding, superheat, and subcooling.
Procedure to check compressor efficiency and guidance on compressor burnout.
Discusses refrigerant piping, compressor burnout cleanup, and system cleaning methods.