9
SYSTEM OPERATION
WARNING
I
F THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
D
O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT
TO
DO
IF
YOU
SMELL
GAS
:
D
O NOT TRY TO LIGHT ANY APPLIANCE.
D
O NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING.
I
MMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S
PHONE.
F
OLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
I
F YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
I
NSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
ELECTRICAL CONNECTIONS
WARNING
T
O
AVOID THE RISK OF ELECTRICAL SHOCK, WIRING TO THE UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
WARNING
HIGH
VOLTAG
E
D
ISCONNECT
ALL
POWER BEFORE SERVICING OR
INSTALLING THIS UNIT.
M
ULTIPLE POWER SOURCES MAY
BE PRESENT.
F
AILURE TO DO SO MAY CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR DEATH.
CAUTION
L
ABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
W
IRING ERRORS CAN COUSE IMPROPER AND DANGEROUS OPERATION.
V
ERIFY PROPER OPERATION AFTER SERVICING.
WIRING HARNESS
The wiring harness is an integral part of this furnace. Field
alteration to comply with electrical codes should not be
required. Wires are color coded for identication purposes.
Refer to the wiring diagram for wire routings. If any of the
original wire as supplied with the furnace must be replaced,
it must be replaced with wiring material having a tempera-
ture rating of at least 105° C. Any replacement wiring must
be copper conductor.
115 VOLT LINE CONNECTIONS
Before proceeding with electrical connections, ensure that
the supply voltage, frequency, and phase correspond to
that specied on the unit rating plate. Power supply to the
furnace must be N.E.C. Class 1, and must comply with all
applicable codes. The furnace must be electrically ground-
ed in accordance with local codes or, in their absence, with
the latest edition of The National Electric Code, ANSI NFPA
70 and/or The Canadian Electric Code CSA C22.1.
An electrical disconnect must be provided at the furnace
location.
NOTE: Line polarity must be observed when making eld
connections.
Connect hot, neutral, and ground wires as shown in the
wiring diagram located on the unit’s blower door. Line
polarity must be observed when making eld connections.
Line voltage connections can be made through either the
right or left side panel.
The furnace is shipped congured for a right side (left side
for counterow) electrical connection with the junction box
located inside the burner compartment. To make electri-
cal connections through the opposite side of the furnace,
the junction box must be relocated to the other side of the
burner compartment prior to making electrical connections.
NOTE: Wire routing must not interfere with circulator blower
operation, lter removal, or routine maintenance.
WARNING
T
O AVOID THE RISK OF ELECTRICAL SHOCK, INJURY, OR DEATH, THE
FURNACE MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL
CODES OR, IN THEIR ABSENCE, WITH THE LATEST EDITION OF THE
N
ATIONAL
E
LECTRIC
C
ODE.
115 VOLT LINE CONNECTION OF ACCESSORIES
(ELECTRONIC AIR CLEANER)
WARNING
HIGH
VOLTAGE
D
ISCONNECT
ALL
POWER BEFORE SERVICING OR
CHANGING ANY ELECTRICAL WIRING.
M
ULTIPLE POWER
SOURCES MAY BE PRESENT.
F
AILURE TO DO SO MAY CAUSE
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Electronic
Air Cleaner
1.0 Amp maximum at 120 VAC
Humidifier 1.0 Amp maximum at 24 VAC
ACCESSORY LOAD SPECIFICATIONS
Turn OFF power to the furnace before installing any acces-
sories. Follow the humidier or air cleaner manufacturers’
instructions for locating, mounting, grounding, and con-
trolling these accessories.
If it is necessary for the installer to supply additional line
voltage wiring to the inside of the furnace, the wiring must
conform to all local codes, and have a minimum tempera-
ture rating of 105°C. All line voltage wire splices must be
made inside the furnace junction box.