EasyManua.ls Logo

Goodman HKS - User Manual

Goodman HKS
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
A
TTENTION
I
NSTALLING
P
ERSONNEL
As a professional installer, you have an obligation to know
the product better than the customer. This includes all safety
precautions and related items.
Prior to actual installation, thoroughly familiarize yourself
with this Instruction Manual. Pay special attention to all
safety warnings. Often during installation or repair, it is
possible to place yourself in a position which is more haz-
ardous than when the unit is in operation.
Remember, it is your responsibility to install the product
safely and to know it well enough to be able to instruct a
customer in its safe use.
Safety is a matter of common sense...a matter of thinking
before acting. Most dealers have a list of specific good safety
practices...follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is
a direct conflict between existing practices and the con-
tent of this manual, the precautions listed here take prece-
dence.
S
AFETY
P
RECAUTIONS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards.
It is the owner’s and installer’s responsibility to read and
comply with all safety information and instructions accom-
panying these symbols. Failure to heed safety information
increases the risk of personal injury, property damage, and/
or product damage.
HIGH VOLTAGE !
D
ISCONNECT
ALL
POWER
BEFORE
SERVICING
.
M
ULTIPLE
POWER
SOURCES
MAY
BE
PRESENT
. F
AILURE
TO
DO
SO
MAY
CAUSE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
ONLY
INDIVIDUALS
MEETING
THE
REQUIREMENTS
OF
AN
“E
NTRY
L
EVEL
T
ECHNICIAN
”,
AT
A
MINIMUM
,
AS
SPECIFIED
BY
THE
A
IR
-
C
ONDITIONING
, H
EATING
,
AND
R
EFRIGERATION
I
NSTITUTE
(AHRI)
MAY
USE
THIS
INFORMATION
. A
TTEMPTING
TO
INSTALL
OR
REPAIR
THIS
UNIT
WITHOUT
SUCH
BACKGROUND
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PERSONAL
INJURY
,
OR
DEATH
.
WARNING
HKS
ELECTRIC HEAT KIT
INSTALLATION INSTRUCTIONS
T
HIS
APPLIANCE
MUST
BE
INSTALLED
FOLLOWING
THE
ANSI/NFPA
70 (N
ATIONAL
E
LECTRIC
C
ODE
)
AND
OTHER
APPLICABLE
CODES
.
WARNING
F
AILURE
TO
FOLLOW
THESE
INSTRUCTIONS
CAN
CAUSE
FIRE
,
EXPLOSION
,
ELECTRICAL
SHOCK
,
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
T
O
AVOID
POSSIBLE
PERSONAL
INJURY
,
USE
EXTREME
CAUTION
IS
USING
POWER
TOOLS
TO
REMOVE
THE
SMALL
BREAKER
MOUNTING
BRACKETS
.
T
HE
BRACKETS
MAY
QUICKLY
ROTATE
AND
CAUSE
INJURY
.
OR
DEATH
.
CAUTION
CARBON MONOXIDE POISONING HAZARD
Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas
Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions. If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.
This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area. Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.
CO can cause serious illness including permanent brain damage or death.
B10259-216
IO-776E
06/2018
Question and Answer IconNeed help?

Do you have a question about the Goodman HKS and is the answer not in the manual?

Summary

Safety Precautions

High Voltage Safety

Disconnect all power before servicing to prevent injury or death.

Carbon Monoxide Hazard

Warning about CO poisoning from devices in enclosed areas.

Installer Qualifications

Only certified technicians should perform installation or repair.

Shipping Inspection

Cargo Damage Reporting

Procedures for inspecting and reporting shipping damage to the carrier.

Standard Air Handler Installation

Approved Air Handler Models

Specifies HKS electric heat kits are only for certain ARU/ARU models.

Installation Safety Guidelines

Mentions minimum height for garage installations and copper conductor use.

Electrical Connections

High Voltage Power Connection Safety

Ensure power is off before making electrical connections.

Wiring Power Supply and Grounding

Instructions for connecting power leads and ground wires.

Low Voltage Signal Wiring

How to connect low voltage control signals using provided connectors.

Three Phase Power Wiring

Wiring terminal block leads for three-phase applications.

25 kW and Three Phase Wiring Diagrams

Install wiring diagrams for 25kW and three phase applications.

Wiring Diagram Marking

Mark the wiring diagram according to installed heater element rows.

Start-Up Procedures

Pre-Start Checks

Verify electrical connections, panel installation, and power supply.

Emergency Heat Test

Test emergency heat setting and observe blower/heat operation.

Multi-Stage Heat Test

Test multi-stage heat operation for kits over 10kW.

Troubleshooting Guidance

Disconnect power and troubleshoot if unit does not cycle appropriately.

Summary

Safety Precautions

High Voltage Safety

Disconnect all power before servicing to prevent injury or death.

Carbon Monoxide Hazard

Warning about CO poisoning from devices in enclosed areas.

Installer Qualifications

Only certified technicians should perform installation or repair.

Shipping Inspection

Cargo Damage Reporting

Procedures for inspecting and reporting shipping damage to the carrier.

Standard Air Handler Installation

Approved Air Handler Models

Specifies HKS electric heat kits are only for certain ARU/ARU models.

Installation Safety Guidelines

Mentions minimum height for garage installations and copper conductor use.

Electrical Connections

High Voltage Power Connection Safety

Ensure power is off before making electrical connections.

Wiring Power Supply and Grounding

Instructions for connecting power leads and ground wires.

Low Voltage Signal Wiring

How to connect low voltage control signals using provided connectors.

Three Phase Power Wiring

Wiring terminal block leads for three-phase applications.

25 kW and Three Phase Wiring Diagrams

Install wiring diagrams for 25kW and three phase applications.

Wiring Diagram Marking

Mark the wiring diagram according to installed heater element rows.

Start-Up Procedures

Pre-Start Checks

Verify electrical connections, panel installation, and power supply.

Emergency Heat Test

Test emergency heat setting and observe blower/heat operation.

Multi-Stage Heat Test

Test multi-stage heat operation for kits over 10kW.

Troubleshooting Guidance

Disconnect power and troubleshoot if unit does not cycle appropriately.

Overview

This document provides installation instructions for the HKS Electric Heat Kit, emphasizing safety precautions and proper installation procedures for professional installers.

Function Description:

The HKS Electric Heat Kit is designed to be installed into specific models of air handlers (ARUFXX14YY, ARPTXX14YY, ASUFXX14YY, ASPTXX14YY, AVPTXX14YY, DVXXPTC14YY) to provide supplemental electric heating. The kit integrates with the air handler's electrical system to deliver heat as needed, controlled by a room thermostat. It includes heating elements, circuit breakers (for some models), and necessary wiring components to ensure safe and effective operation. The installation process involves mounting the heat kit within the air handler, connecting high and low voltage wiring, and performing a start-up sequence to verify functionality.

Important Technical Specifications:

  • Compatibility: Designed for specific ARUFXX14YY, ARPTXX14YY, ASUFXX14YY, ASPTXX14YY, AVPTXX14YY, and DVXXPTC14YY air handler models. The "XX" in the model numbers refers to the two-digit size, and "YY" refers to revision letters.
  • Electrical Requirements: The kit requires connection to a high voltage power supply. For two power supply electric heat kits, installers must check the air handler rating plate for Minimum Circuit Ampacity and Maximum Overcurrent Protection electrical ratings for each circuit.
  • Circuit Breakers: Some electric heat kits include circuit breakers. For 25kW applications, circuit breakers are supplied separately and must be attached to the heater plate. For downflow applications with circuit breakers, they must be rotated 180 degrees so the "ON" position is up.
  • Wiring: The kit includes lugs for high voltage power supply connections and a female multi-pin connector for low voltage connections. For three-phase applications, terminal block leads must be wired to the transformer as per the wiring diagram.
  • Ventilation (Carbon Monoxide Warning): While the electric heat kit itself does not produce carbon monoxide, the manual includes a critical warning regarding installation in enclosed areas (garages, utility rooms, parking areas) where other carbon monoxide producing devices (e.g., automobiles, space heaters, gas water heaters) might be present. Adequate, direct outside ventilation is required in such scenarios to prevent CO poisoning, as the air handler could recirculate CO emissions throughout the structure.
  • Installation Height (Garages): When installed in a garage, the heating element must be at least 18 inches above the floor to prevent personal injury or death.
  • Conductor Material: Only copper conductors should be used to avoid property damage or personal injury due to fire.

Usage Features:

  • Supplemental Heating: Provides electric heating to complement the air handler's primary function, ensuring comfort in various conditions.
  • Thermostat Control: Operation is governed by a room thermostat, allowing users to set desired temperatures and activate emergency heat functions.
  • Staged Heating: For kits with more than 10kW, the heating elements turn on in stages, with the first 10kW activating within 10-30 seconds of a call for heat, and additional stages activating subsequently.
  • Airflow Direction: The electric heat kit must be installed with the airflow decal pointing in the correct direction to ensure proper operation and heat distribution.

Maintenance Features:

  • Professional Installation: The manual explicitly states that only individuals meeting the requirements of an "Entry Level Technician" (as specified by AHRI) should install or repair the unit. This ensures proper installation and reduces the likelihood of product damage, personal injury, or death.
  • Pre-Installation Inspection: Installers are required to thoroughly inspect the kit upon arrival for any damage, loose screws, or wires, and to document any issues with the carrier.
  • Electrical Safety: Emphasizes disconnecting all power before servicing and being aware of multiple power sources to prevent electrical shock, property damage, personal injury, or death.
  • Wiring Diagram: For 25kW and three-phase heat kit applications, a wiring diagram is provided and must be installed in a prominently visible location on the exterior of the unit. Installers must also mark the diagram to indicate the number of heater element rows installed.
  • Start-Up Procedure: A detailed start-up sequence is provided to verify proper electrical connections, circuit breaker functionality, blower operation, and heating element activation, including specific timing for heat stages. An ammeter is required during start-up to monitor power supply.
  • Troubleshooting: If the blower or electric heat does not cycle appropriately during start-up, installers are instructed to disconnect all power supplies and troubleshoot according to service manual instructions.
  • Quality Assurance: The manufacturer highlights that their systems are designed and manufactured with high-quality standards, run-tested before leaving the factory, and use quality materials and components to reduce frequent causes of product failure, implying a focus on reliability and ease of service.

Goodman HKS Specifications

General IconGeneral
BrandGoodman
ModelHKS
CategoryElectric Heater
LanguageEnglish