43-200 Pszczyna, ul. Staromiejska 31b
tel. 032 326 30 70, fax 032 447 73 30
www.gorke.com.pl, e-mail: biuro@gorke.com.pl
SPECIFICATION AND USER’s MANUAL
type of the device: 2-channel set, type: RSU KO2/2
the set contains: 2-channel RSU KO2/2 receiver and two 2-button PUK 102 remote controls
TECHNICAL PARAMETERS OF THE RECEIVER
class: C
type of receiving module: superreaction
sensitivity: -100 dBm
frequency: 433,92 MHz
radio transmission: Keeloq hopping code by Microchip
Technology
memory capacity: 14
voltage supply:
- nominal: 12 V DC
- allowable: 10-15 V DC
power consumption:
- static: 17 mA
- maximal: 60 mA
capacity:
- relay output: 1A/ 30 V DC
- S transistor output: 0,5A/ 12 V DC
- sabotage output: 50mA/ 12 V DC
number of relays: 2
relay's operating mode: mono or bistable
time scope for the mono mode: ~1s-4min20s
operating temperature range: 0 to +40
dimensions (mm): 48*68*26
cooperation: any GE sender
operating range (m)*: 100-500
colour: white
* range depends on the type of the sender
TECHNICAL PARAMETERS OF THE REMOTE CONTROL
class: C
frequency: 433,92 MHz
transmission: coded (Keeloq hopping code by Microchip
Technology)
number of buttons: 2
sending power: <5mW
power supply: 1 battery 12V
dimensions (mm): 29*61*11
colour: black
cooperation: any GE receiver
operating range (m):
- with superreactive receiver: 100
- with heterodyne receiver: 200
The operating range: the following range (100m) concerns the open space (without any obstacles, when the
receiver and the remote control can “see each other”). If there are any obstacles between the receiver and the
sender, one must assume that the range would be reduced: for wood and plaster it would be 5-20% lower, for
bricks 20-40% lower, and for reinforced concrete 40-80% lower. If there are many obstacles we advise to
configure sets using the receivers of the SH class, to use retransmitters or stronger remote controls. If there are
metal obstacles, using the radio systems is not recommended. In such situation, one should consider installing
WLC 201 module, which helps to avoid the problem. The double value given in the technical specification of the
remote control concerns cooperating with different types of receivers. The first value (the smaller one) concerns
the superreactive receivers of the RSU type, the second one (the larger one) – with the superheterodyne
receivers, for example OPC, IDO.
Gorke Electronic
SPECIFICATION AND USER’s MANUAL: 2-channel RSU-KO2/2 set page: 1
Question and Answer IconNeed help?

Do you have a question about the Gorke Electronic RSU KO2/2 and is the answer not in the manual?

Gorke Electronic RSU KO2/2 Specifications

General IconGeneral
BrandGorke Electronic
ModelRSU KO2/2
CategorySecurity System
LanguageEnglish

Summary

Technical Parameters of the Receiver

Technical Parameters of the Remote Control

Purpose of the Elements

Diode Controls and Learning Button

Describes the function of SUPPLY, CHANNEL 1, and K2 diodes, and the LEARNING button.

Antisabotage and Signal Output

Explains the ANTISABOTAGE circuit connection and the S output for acoustic signaling.

Receiver Installation Conditions

Transmission Code and Basic Operation

Transmission Code

Details the KeeLoq hopping code for high safety and the need to program remotes.

Principal Use Cases

Outlines the receiver's use in controlling gates, locks, lights, and alarm systems.

Operating Frequency

Specifies the device operates on 433.92 MHz, common in the EU.

Registering Remote Controls

Registering a Two-Button Remote

Step-by-step guide to register a 2-button remote control on the receiver.

Registering a One-Button Remote (Channel 1)

Procedure for registering a 1-button remote to control channel 1 of the receiver.

Registering a One-Button Remote (Channel 2)

Procedure for registering a 1-button remote to control channel 2 of the receiver.

Receiver Settings and Memory Management

Setting Receiver Operating Mode

Instructions on setting channel 1 to bistable and channel 2 to monostable mode.

Deleting Remote Controls from Memory

Process for clearing all programmed remote controls from the receiver's memory.