8
WARNING:Readallthesafetywarningsandinstructionsandstorethemsafelyfor
futurereference.Failuretoadheretothesewarningsmayresultinseriousinjuryand
damagetoequipment.
OTTOVACliftingcapacity
NOTICE:TheOTTOVAChasbeentestedupto200kg(440lbs)atmaximumliftingforce
underidealtestconditions.However,thistestweightfigureisthebreakingpointunder
optimallaboratorytestconditionsandmustneverbereachedinanyreal-world
application!
Localregulationsmayrequiredifferentsafetymarginstobeusedandtheofficialdevice
WorkingLoadLimit(WLL)hasbeensetto100kg(220lbs)basedona2:1ratioand66kg
(145lbs)ona3:1ratioforanon-poroussurface.TheWorkingLoadLimitof100kg(220
lbs)is50%ofthemaximumliftingforcetestedand66kg(145lbs)is33%ofthemaximum
liftingforcetestedunderidealconditions(200kg/440lbs)andthisWorkingLoadLimit
mustbeadheredtowhenworkingincountrieswherethe2:1and3:1safetymargin
applies.Usethechartbelowtoestimatesafeliftingvalues:
WLL:2:1ratioof100kg(220lbs),3:1ratioof66kg(145
lbs)onnon-poroussurfaces
IMPORTANT:Theliftingforceishighlydependentontheliftedsurfaceandfactorssuch
astemperature,altitude(ambientpressure),andotherfactors.
AlwayscheckthepressuredisplayedontheOTTOVACvacuumgaugeanddonotrely
solelyontheestimatedmaximumliftingforceschartwhenliftingdifferentmaterials,
sincedifferentfactorsrelatingtoyourspecificapplicationmayreducethelifting
capabilitiesofthedevice.