CAUTION
: Take care not to vacuum up the Firebox Washer or apply too much
vacuum to the opening that the washer fits into. Failure to do this might result in drawing a piece
of corn up the pressure tube in the hopper thus plugging it. This could result into excessive
smoke in the hopper.
Replace the plug in the Grain Comfort Stove then tighten finger tight.
Note: It may be advantageous to disassemble the exhaust system and take outside to clean to
avoid a potential mess. Reassemble everything back together, and you are ready to heat again.
Note: Routinely check to see if the Muffler Screen is blocked, this will cause exhaust flow
problems
ANNUAL MAINTENANCE
FREE STANDING INSTALLATION:
The Venting System should be thoroughly checked and cleaned. Piping should be replaced if
suspect and any leaks in the Flanging arrangement should be repaired.
The Outside portion of the Venting System should be covered during the summer months with a
plastic bag in order to prevent foreign matter from entering the stove.
Any Fuel should be removed from the Hopper if the Stove is not going to be operated for a while
The blowers must be lubricated according to manufacturer’s instructions as given on the motor
housing. Two oil points are clearly marked on each blower. Use a good quality light machine oil.
Be sure to unplug the power supply cord before lubricating.
NOTE: Both fans have oiling points placed at the bearing ends of the motor.
22