Door System Settings
Notes: Remote SIP phone needs password (digits 0-9 only, ended with # key) matching the configuration on the web page to open the door (via
DTMF).
GDS3710 support RFID for multiple users to open door, therefore every user has its own PIN. For environment with large number of users (limit is
2000), it’s difficult for the GDS3710 to manage all these users, so a separate PC or Server should be involved for such kind of management and
monitoring.
In environments with large number of users (limit is 2000), the GDS3710, another possibility would be to set one unified Local PIN for opening the
door for all the users.
Using Alarm Out (COM 1) to Control a Second Door
Starting from firmware 1.0.5.2, user can now set Alarm_Out (COM1) interface to control a second Door, in additional to the existing Locker/COM2
interface (controlling Door1).
This feature allows GDS3710 to control the operation of two doors via RFID, local and remote PINs.
For example, a 3 party Wiegand Input device or GDS3710 can be installed at Door2 with related cable wired into the control GDS3710 installed at
Door1. The Door1 and Door2 can be configured to be open by programmed RFID cards, PINs either separately or both.
Alarm_Out1 Feature
Interface for Door Control (which Door can be OPEN):
If Alarm_Out (COM1) interface is set to control Door 2 opening, “ALMOUT1 Status” can be configured by choosing “Normal Open” or “Normal Close”
based on the strike used.
Unlike default COM2 which is designed for strike control and having three connecting sockets, the COM1 only has two connecting sockets.
Therefore correct lock mode has to be configured to make the strike working as expected.
For above example, the GDS3710 is configured to control Door1 (wiring to COM2 interface); the 3 party Wiegand Input is set to control Door2
(wiring to COM1 interface).
● DTMF: Tones will be played when pressing the GDS3710 keys.
● Mute: No sound will be played when pressing keys.
Enable Wiegand Input
This option needs to be enabled when GDS is connected to the wiegand. output device (RFID card reader for
example)
Wiegand Output
This option is to be enabled when the GDS is the wiegand output device. (example: input device is a door
controller)
rd
rd