Using PoE as power supply (Suggested)
Connect the other end of the RJ45 cable to the PoE switch.
PoE injector can be used if PoE switch is not available.
Using the power adapter as power supply (PSU not provided)
Connect the other end of the RJ45 cable to network switch or router.
Connect DC 12V power source via related cable to the corrected PIN of the GDS371x.
GDS371x Wiring Connection
Jack Signal Function Note
J2 (Basic)
3.81mm
TX+
Ethernet
PoE 802.3af
Class 3, 12.95W
Orange / White
Data
TX- Orange
RX+ Green / White
RX- Green
PoE_SP2 Blue + Blue/White
Please twist these two
wires together and connect
to SP1, SP2 respectively
even the PoE NOT used.
PoE_SP1 Brown + Brown/White
GND
Power Supply DC 12V, 1A Minimum
12V
J3 (Advanced)
3.81mm
GND Alarm GND
ALARM1_IN+
Alarm In Vin<15V
ALARM1_IN-
ALARM2_IN+
ALARM2_IN-
NO1
Alarm Out Relay: 30VDC/2A; 125VAC/0.5A
COM1
NO2
Electric Lock
For "Fail Secure" (Locked when Power Lost) Strike,
connect COM2 & NO2.
For "Fail Safe" (Open when No Power) Magnetic Lock,
connect COM2 & NC2.
Relay: 30VDC/2A; 125VAC/0.5A
COM2
NC2
J4 (Special)
2.0mm
GND Wiegand Power GND Black
Both Input and Output
MUST be connected