EasyManua.ls Logo

Gree Cozy GWC05MA-K1NNA9A

Gree Cozy GWC05MA-K1NNA9A
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Procedures / Photos
Unscrew the 4 screws fixing the motor to take out
the motor,and then unscrew the 2 screws fixing the
motor support to take it out.
Unscrew the fastening nut of the four-way valve
coil and remove the coil. Wrap the four-way valve
with wet cotton and unsolder the 4 weld spots
connecting the four-way valve to take it out. (Note:
Refrigerant should be discharged firstly.)
Welding process should be as quick as possible
and keep wrapping cotton wet all the time. Be
sure not to burn out the lead-out wire of
compressor.
7. Disassemble Motor and Motor Support
8. Disassemble Four-way Valve
Four-way valve
Screws
Weld spots
Screws
Four-way valve coil
Motor
Respectively unsolder the weld spots of main
capillary and auxiliary capillary to take off the
capillary.
9. Disassemble Capillary
Capillary

Related product manuals