U-Match Series DC Inverter Service Manual
128
4. Assemble
compressor
1. Fix the new compressor
on to the chassis;
2. Connect the suction port
and discharge port of
compressor with the system
pipes;
3. Properly connect the
pwoer cord of compressor;
4. Renew the compressor
electric heating belt and
discharge temperature
sensor;
5. Check if the compressor
rotates in reverse and if the
lubricant have leaked.
5. Assemble unit
Assemble the unit in the
reverse procedures of
disassembly.
18k
Disassembly and Assembly of external casing
Remark :
Step
Illustration
Handling Instruction
1. Remove external
casing
1. Remove the top cover and
handle;
2. Remove the grille, outer
case and right side plate.
2. Remove motor
1. Remove the blade nut and
then remove the blade;
2. Remove the motor from
motor support.