What to do if my Gree Golden has the built-in heat protector of the motor breaks frequently?
- FFrank HaynesSep 10, 2025
Replace the fan motor of your Gree Air Conditioner.
What to do if my Gree Golden has the built-in heat protector of the motor breaks frequently?
Replace the fan motor of your Gree Air Conditioner.
How to fix a Gree Golden with a damaged motor?
Replace the motor of your Gree Air Conditioner.
How to fix a Gree Golden with a damaged IC board?
Replace the circuit board of your Gree Air Conditioner.
What to do if my Gree Golden Air Conditioner has the indoor fan motor is burned or breaks or has the heat protector malfunction?
Replace the fan motor or the defective part of your Gree Air Conditioner.
What to do if my Gree Golden has a protector itself has malfunction?
Replace the protector of your Gree Air Conditioner.
What to do if my Gree Golden has a motor damaged?
Replace the motor of your Gree Air Conditioner.
What to do if my Gree Golden has a torque of the swing motor that is not enough?
First, check whether the connection is wrong on your Gree Air Conditioner. If not, replace the parts.
What to do if my Gree Golden Air Conditioner has a compressor that shakes too much?
Adjust the support washer of the compressor, and tighten any loose screws on your Gree Air Conditioner.
What to do if my Gree Golden has the refrigerant has leakage or is insufficient?
Check and fill the leakage, then vacuumize it and supplement the refrigerant as required on your Gree Air Conditioner.
What to do if my Gree Air Conditioner remote controller is short of power?
Change the batteries in your Gree Air Conditioner remote controller.
Details dimensions and mounting for indoor units.
Details dimensions and mounting for outdoor units.
Explains remote controller functions for 09K/12K models, including parameters and modes.
Details cooling, DRY, HEAT modes, and protection mechanisms.
Covers memory, timer, auto, buzzer, sleep, and fan functions.
Details remote controller functions for 18K/24K models, including parameters and modes.
Lists causes and solutions for unit startup failures.
Addresses issues with refrigerant flow and air circulation affecting cooling/heating.
Troubleshoots fan operation issues, including motor, capacitor, and wiring.
Diagnoses compressor overheating issues related to voltage, wiring, refrigerant, and protectors.
Provides solutions for swing fan malfunction due to connection, controller, or motor issues.
Covers troubleshooting for water leakage and abnormal noises or vibrations.
| Power Supply | 220-240V, 50Hz |
|---|---|
| Cooling Capacity | 12000 BTU/h |
| Heating Capacity | 12000 BTU/h |
| Refrigerant | R32 |
| Energy Efficiency Rating (EER) | 3.5 |
| Features | Sleep Mode, Turbo Mode |
| Energy Efficiency Ratio (EER) | 3.5 |
| Noise Level | 50 dB (Outdoor) |
| Operating Temperature (Cooling) | 18°C to 43°C |
| Operating Temperature (Heating) | 24°C |
| Type | Split Air Conditioner |