U-Match Series DC Inverter Service Manual
131
3. Remove gas liquid
separator
1. Discharge the refrigerant
inside the pipeline and
recycle the refrigerant during
discharging;
2. Unsolder the 4-way valve
assy from gas liquid
separator;
3. Remove the gas liquid
separator.
1. Discharge the refrigerant
inside the pipeline and
recycle the refrigerant during
discharging;
2. Unsolder the 4-way valve
assy from compressor;
3. Remove the nut fixing
compressor;
4. Take away the compressor
from chassis.
Assemble the unit in the
reverse procedures of
disassembly.
Disassembly and Assembly of external casing
1. Remove external
casing
1. Remove the top cover and
handle;
2. Remove the grille, outer
case and right side plate.