GREE U-Match 5 SERIES UNIT SERVICE MANUAL
116
Removal of fan and motor
Note: Before removing the motor, power must be cut off.
Step
Picture
Work instruction
9. Install the water tray.
Direct the 4 corners of water
tray to the 4 corners of the unit
and then press them. Use a
screwdriver to tighten the
screws in the 4 corners.
Connect the power cord and
water pump wire.
Place back the cover of
electric box and the clamp of
power cord. Then tighten the
screws with a screwdriver.
Removal and installation of drain pump
Step
Picture
Work instruction
1. After removing the front
panel as instructed above,
loosen the screws of the
water tray.
Use a screwdriver to loosen
the screws of water tray.
2. Remove the cover of
electric box and the clamp
of power cord.
Twist off the screws and open
the cover of electric box and the
clamp of power cord.
3. Remove the motor wire
and water pump wire.
Remove the motor wire and
water pump wire in the electric
box.