EasyManua.ls Logo

Gree GUD160ZD/A-T User Manual

Gree GUD160ZD/A-T
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Owner's Manual
Original Instructions
Air Conditioners
DC Inverter U-match Series Floor ceiling Type Unit
Models:
Indoor Unit Outdoor Unit
GUD35ZD/A-T GUD35W/NhA-T
GUD50ZD/A-T GUD50W/NhA-T
GUD71ZD/A-T GUD71W/NhA-T
GUD85ZD/A-T GUD85W/NhA-T
GUD100ZD/A-T GUD100W/NhA-T GUD100W/NhA-X
GUD125ZD/A-T GUD125W/NhA-T GUD125W/NhA-X
GUD140ZD/A-T GUD140W/NhA-T GUD140W/NhA-X
GUD160ZD/A-T GUD160W/NhA-X

Other manuals for Gree GUD160ZD/A-T

Question and Answer IconNeed help?

Do you have a question about the Gree GUD160ZD/A-T and is the answer not in the manual?

Gree GUD160ZD/A-T Specifications

General IconGeneral
Power Supply380-415V, 3Ph, 50Hz
RefrigerantR410A
Weight (Indoor Unit)45 kg
TypeDucted
Noise Level (Indoor)48 dB(A)

Summary

3 Installation

3.1 Installation Preparation

Covers pre-installation checks, refrigerant safety, and general requirements before installation.

3.1.2 Selection of Installation Location

Guides on choosing suitable indoor and outdoor installation sites, considering wind and sunlight.

3.4 Vacuum Pumping and Leak Detection

3.4.1 Vacuum Pumping Procedure

Instructions for evacuating the refrigerant circuit to remove air and moisture.

3.4.2 Leak Detection Methods

Approved methods for identifying any leaks in the refrigerant system.

4 Electrical Installation

4.1 Requirements and Notices

Essential requirements and safety warnings for performing electrical installation.

4.3 Power and Communication Cord Connection

Instructions for correctly connecting power cords and communication wires between units.

6 Maintenance and Troubleshooting

9 Maintenance Precautions

9.1 Servicing Information and Safety

Essential safety information and procedures for technicians working with flammable refrigerants.

9.3 Refrigerant and Ignition Controls

Procedures for checking refrigerant, ensuring fire extinguisher availability, and prohibiting ignition sources.

9.6 Refrigerant Handling Procedures

Steps for refrigerant removal, evacuation, charging, and decommissioning, including safety protocols.

9.7 Charging and Decommissioning

Detailed procedures for charging the system and safely decommissioning the unit.

9.10 Refrigerant Detection and Removal

Procedures for detecting flammable refrigerants and safe removal and evacuation processes.

9.11 Charging Procedures

Specific requirements and safety measures for charging the refrigeration system.

9.12 Decommissioning Procedures

Steps for safely decommissioning the unit, including refrigerant recovery and system isolation.

Related product manuals