GREE                                                                                                    U-Match 5 SERIES UNIT SERVICE MANUAL
 
120 
 
Note:  Before  removal,  make  sure  power  is  cut  off.  During  the  removal  procedure,  take  good  care  of  all  the 
components.   
1.Remove the cover 
plate.   
●Loosen the screws of cover 
plate and then remove the 
cover plate. (As shown in the 
picture, the circle indicates 6 
screws of the cover plate.) 
 
2. Remove the water 
tray.   
●Loosen the screws of water 
trap. Pull it up and remove it. 
The removed water tray is as 
shown in the picture.   
 
Note: Make sure power is cut off. Take good care of the copper pipe and aluminum fins. If the removal takes a long 
time, please put the copper pipe under pressure.   
1. Remove the screws 
on the side plate of 
evaporator.   
●Remove the screws of 
evaporator and the screws 
that connect the upper 
cover plate to the left and 
right side plates.   
2. Remove the sealing 
plate the connects to 
the evaporator valve 
and the screws that 
connect to the flange.   
●Remove the screws of 
the sealing plate of valve. 
Then remove the sealing 
plate of valve. Remove the 
screws that connect the 
evaporator to the flange.