5 Maintenance
5.1 Failures Not Caused by Faults of the AC
(1) If your air conditioner fails to function normally, please first check the following
items before maintenance:
Problem
Cause
Corrective measure
The air
conditioner
can't run.
If you turn off the unit and
then immediately turn it on,
in order to protect the
compressor and avoid
system overload,
compressor will delay
running for 3min.
Please wait for a while.
Wire connection is wrong.
Connect wires according to the
wiring diagram.
Fuse or circuit breaker is
broken.
Replace the fuse or switch on
the circuit breaker.
Power failure.
Restart after power is resumed.
Power plug is loose.
Re-insert the power plug.
Remote control has low
battery.
Replace the batteries.
Bad cooling or
heating effect.
Air inlet and outlet of indoor
or outdoor units have been
blocked.
Clear the obstacles and keep
the room for indoor and outdoor
units well ventilated.
Improper temperature setting
Reset a proper temperature.
Fan speed is too low.
Reset a proper fan speed.
Air flow direction is not right.
Change the direction of air
louvers.
Doors or windows are open.
Close them.
Exposed under direct
sunshine
Put on curtains or louvers in
front of the windows.
Too many heat sources in
the room.
Remove unnecessary heat
sources.
Filter is blocked or dirty.
Send for a professional to clean
the filter.
Air inlets or outlets of the
units are blocked.
Clear away obstacles that are
blocking the air inlets and
outlets of indoor and outdoor
units.

Other manuals for Gree GUD71ZD/A-T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GUD71ZD/A-T and is the answer not in the manual?

Gree GUD71ZD/A-T Specifications

General IconGeneral
RefrigerantR410A
Compressor TypeRotary
Power Supply220-240V, 50Hz
TypeSplit
Operating Temperature (Cooling)18°C to 43°C
Operating Temperature (Heating)-7°C to 24°C

Related product manuals