U-Match Series DC Inverter Service Manual
10
Model
Indoor unit
GTH36D3FI
GTH42D3FI
GTH48D3FI
Product Code
ED020N1101
ED020N1130
ED020N1111
Outdoor unit
GUHD36ND3FO
GUHD42ND3FO
GUHD48ND3FO
Product Code
CF090W0771
CF090W0840
CF090W0781
Capacity
Btu/h
34000(10800~39000)
39500(12000~42500)
48000(20400~50500)
Btu/h
41000(9800~49500)
44000(13000~52500)
54500(17500~61500)
Power Input
kW
3.28(0.80~4.60)
4.05(0.60~4.70)
4.95(1.30~5.50)
kW
3.75(0.65~4.80)
4.05(0.69~4.80)
4.60(1.20~5.40)
SEER / HSPF
(Btu/h)/W
16.00/9.00
16.00/9.00
16.00/9.00
Indoor Unit
GTH36D3FI
GTH42D3FI
GTH48D3FI
Power Supply
V/Ph/Hz
208/230V~ 60Hz
208/230V~ 60Hz
208/230V~ 60Hz
Heat Exchange
-
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Fan
-
Direct
Direct
Direct
kW
0.15×1
0.15×1
0.25×1
m
3
/h(CFM)
1900(1115)
1900(1115)
2300(1350)
Sound Pressure Level(SS/H/M/L)
dB(A)
54/53/51/46
55/54/52/47
56/55/50/46
Air Filter
-
PP
PP
PP
Drain Piping
mm(inch)
Φ17×1.75
0.60.07)
Φ17×1.75
0.60.07)
Φ17×1.75
0.60.07)
Outline Dimensions (W×D)
mm(inch)
1420×245×700
(55.9×9.6×27.6)
1420×245×700
(55.9×9.6×27.6)
1700×245×700
(66.9×9.6×27.6)
Net Weight
kg(lb)
48.0(105.8)
50.0(110.3)
59.0(130.1)
Outdoor Unit
GUHD36ND3FO
GUHD42ND3FO
GUHD48ND3FO
Power Supply
V/Ph/Hz
208/230V~ 60Hz
208/230V~ 60Hz
208/230V~ 60Hz
Heat Exchange
-
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Compressor
-
Rotary
Rotary
Rotary
W
4150
4150
4580
Refrigerant
-
Electronic Expansion
Valve
Electronic Expansion
Valve
Electronic Expansion
Valve
kg(oz)
3.5(123.5)
3.7(130.5)
4.0(141.1)
Outline Dimensions (W×D)
mm(inch)
1107×110440
(43.6×43.17.3)
951349×412
(37.7×53.16.2)
951349×412
(37.7×53.16.2)
Net Weight
kg(lb)
93.0(205.1)
95.0(209.5)
105.0(231.5)
Piping
Connections
Inch
Φ3/8
Φ3/8
Φ3/8
Inch
Φ5/8
Φ5/8
Φ5/8
m(ft)
30(98.4)
50(164.0)
50(164.0)
m(ft)
15(49.2)
30(98.4)
30(98.4)
Note:
Nominal capacities are based on the follow conditions.
Indoor
Outdoor
Cooling
DB: 26.7(80.0)
WB: 19.4(67.0)
DB: 35.0(95.0)
WB: 23.9(75.0)
Heating
DB: 21.1(70.0)
WB: 15.6(60.0)
DB: 8.33(47.0)
WB: 6.11(43.0)
Piping Length
18k~48k units
7.6m(25.0ft)
The air volume is measured at the relevant standard external static pressure.
Noise is tested in the Semi anechoic room, so it should be slightly higher in the actual operation due to
environmental change.