EasyManuals Logo

Gree GWC09QC-A3DNA1D User Manual

Gree GWC09QC-A3DNA1D
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
50
Installation and Maintenance
Service Manual
4. Communication malfunction E6
Start
Cut off power supply. Check if
connection line of IDU and ODU
and the wire inside electric box
are correctly connected.
Correct connection?
Main board matches
with display board? Main board of
IDU matches with that of ODU?
Communication cord is damaged?
Replace IDU's
main board
Malfunction eliminated?
End
Connect the line
according to
wiring diagram.
Match correctly
according to product
specification
Replace
communication
cord
Replace ODU's
main board.
Malfunction eliminated?
Malfunction eliminated?
Malfunction eliminated?
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWC09QC-A3DNA1D and is the answer not in the manual?

Gree GWC09QC-A3DNA1D Specifications

General IconGeneral
BrandGree
ModelGWC09QC-A3DNA1D
CategoryAir Conditioner
LanguageEnglish

Related product manuals