Install indoor unit
Connect indoor and outdoor electric wires
1. Open the surface panel.
2. Remove the wiring cover
Fig.6.
3
. Route the power connection cord from the
back of the indoor unit and pull it toward the
4. Connect the interconnection cord to the terminal block, and then fix the cord with cord anchorge.
5. Reassemble the clampand wiring cover.
front through the wiring hole for connection.
6. Recover the surface panel.
Install the water drainage pipe
N(1)
2
3
blue black
brown
yellow-
green
outdoor unit connection
N(1)
2
3
blue black
brown
yellow-
green
outdoor unit connection
for some model
for some model
Fig.6
Wiring cover
1.
2.
3.
Connect the drain hose to the outlet pipe of the indoor unit.
Bind the joint with rubber belt.
Put the drain hose into insulating tube.
Wrap the insulating tube with wide rubber belt to
prevent
the shift of insulating tube. Slant the drain hose downward
slightly for smooth drainage of condensate
.
bulge
distortion
outlet pipe of
indoor unit
insulating tube
connected
insulating tube
drain hose
outlet pipe of
indoor unit
drain hose
outlet pipe of
indoor unit
outlet pipe of
indoor unit
rubber belt
rubber belt
rubber belt
Flooded
Note: The insulating tube should be connected reliably
withthe sleeve outside the outlet pipe. The
drain hose should be slanted downward
slightly, without distortion, bulge or fluctuation.
Do not put the outlet in the water.