36
Installation and Maintenance
Service Manual
(1) Take  sufficient  protective  measures  when  installing  the 
outdoor unit.
(2) Make sure the support can withstand at least four times the 
unit weight.
(3) The outdoor unit  should  be installed at  least  1  3/16 inch 
above the oor in order to install drain joint.(As show in Fig.18)
(4)  For  the  unit  with  cooling  capacity  of  2300W~5000W,  6 
expansion screws are needed; for the unit with cooling capacity 
of 6000W~8000W, 8 expansion screws are needed; for the 
unit with cooling capacity of 10000W~16000W, 10 expansion 
screws are needed.
(1) After tightening  the  screw,  pull the power  cord  slightly to 
check if it is rm.
(2) Never cut the power connection wire to prolong or shorten 
the distance.
(1) The through-wall height of drain hose shouldn't be higher 
than the outlet pipe hole of indoor unit.(As show in Fig.25)
(2) Slant  the  drain hose slightly  downwards. The  drain hose 
can't be curved, raised and uctuant, etc.(As show in Fig.26)
Note:
Note:
Note:
8.6 Installation of Outdoor Unit
1. Fix the Support of Outdoor Unit(Select it according to 
the actual installation situation)
(1) Select installation location according to the house structure.
(2) Fix the support of outdoor unit on the selected location with 
expansion screws.
5. Connect Outdoor Electric Wire
(1) Let the connection wire sleeve go through the two holes of 
bafe; tighten the connection joint of sleeve and bafe; remove 
the wire clip;  connect  the  power  connection  wire  and  power 
cord to the wiring terminal according to the color; x them with 
screws.(As show in Fig.23)
6. Neaten the Pipes
(1) The pipes should be placed along the wall, bent reasonably 
and hidden possibly. Min. semidiameter of bending the pipe is 3 
15/16inch.
(2) If the outdoor unit is higher than the wall hole, you must set 
a U-shaped curve  in the pipe before pipe  goes into the room, 
in order to prevent rain from getting into  the room.(As show in 
Fig.24)
(2) Fix the power connection wire and power cord with wire clip.
(3)  Fix the stopper on handle with screw.
2. Install Drain Joint(only for cooling and heating unit)
(1) Connect the outdoor drain joint into the hole on the chassis.
(2) Connect the drain hose into the drain vent.
(As show in Fig.19)
3. Fix Outdoor Unit
(1) Place the outdoor unit on the support.
(2) Fix the foot holes of outdoor unit with bolts.
(As show in Fig.20)
4. Connect Indoor and Outdoor Pipes
(1) Remove the screw on the right handle and valve cover of 
outdoor unit and  then remove  the handle  and valve cover.(As 
show in Fig.21)
(2) Remove the screw cap of valve and aim the pipe joint at the 
bellmouth of pipe.(As show in Fig.22)
(3) Pretightening the union nut with hand.
(4) Tighten the union nut with torque wrench .
Hex nut diameter(inch) Tightening torque(ft·Ibf)
Φ1/4 11.10~14.75
Φ3/8 22.12~29.50
Φ1/2 33.19~40.56
Φ5/8 44.24~47.94
Φ3/4 51.32~55.31
Refer to the following table for wrench moment of force
:
Fig.18 Fig.19
Fig.20
Fig.21
Fig.22
Fig.23
Fig.24
Fig.25
U-shaped curve