20
7HFKQLFDO,QIRUPDWLRQ
Service Manual
Ĺ
:KHQWXUQLQJRIIWKHXQLWKRUL]RQWDOORXYHUZLOOFORVHDWSRVLWLRQ2
ĺ
6ZLQJDFWLRQLVYDOLGRQO\ZKHQVHWVZLQJFRPPDQGDQGWKH,'8IDQPRWRULVRSHUDWLQJ
(8) Dual-8 nixie tube display
ƹ
:KHQWKHDLUFRQGLWLRQHULVWXUQHGRQIRUWKH¿UVWWLPHGXDOQL[LHWXEHGHIDXOWHGWRGLVSOD\FXUUHQWVHWWHPSHUDWXUH
ƹ
:KHQFRQWUROOHUUHFHLYHVVLJQDORIGLVSOD\VHWWHPSHUDWXUHGXDOQL[LHWXEHGLVSOD\VVHWWHPSHUDWXUH:KHQUHFHLYHGUHPRWHFRQWURO
VLJQDOLVVZLWFKHGWRLQGRRUDPELHQWWHPSHUDWXUHGLVSOD\VWDWXVVLJQDOIURPRWKHUGLVSOD\VWDWXVGXDOQL[LHWXEHZLOOGLVSOD\LQGRRU
DPELHQWWHPSHUDWXUHIRUVDQGWKHQWXUQEDFNWRGLVSOD\VHWWHPSHUDWXUH,IUHPRWHFRQWUROWRVHWRWKHUVWDWXVWKHGLVSOD\NHHSVWKH
same.
ƹ
:KHQDLUFRQGLWLRQHUKDVDPDOIXQFWLRQGXDOQL[LHWXEHZLOOVKRZUHOHYDQWHUURUFRGH
ƹ
+HDWLQJLFRQLVEULJKWIRUDSHULRGWLPHDQGWKHQ2))IRUVRPHPRGHOV
ƹ
,IWXUQRIIOLJKWEXWWRQDOOGLVSOD\ZLOOEHWXUQHGRII
(9) Memory function
ķ
3RZHUIDLOXUHZKHQWXUQLQJRQWKHXQLW
ƹ
0HPRU\FRQWHQW21VWDWXVPRGHXSGRZQVZLQJOLJKWVHWWHPSHUDWXUHVHWIDQVSHHGJHQHUDOWLPHU)DKUHQKHLW&HOVLXV
ƹ
General timer can be memorized. Time of timer is calculated again from energization.
ƹ
&ORFNWLPHUFDQ¶WEHPHPRUL]HG
ĸ
3RZHUIDLOXUHZKHQWXUQLQJRIIWKHXQLW
ƹ
0HPRU\FRQWHQW2))VWDWXVPRGHXSGRZQVZLQJOLJKWVHWWHPSHUDWXUHVHWIDQVSHHGJHQHUDOWLPHU)DKUHQKHLW&HOVLXV
ƹ
General timer can be memorized. Time of timer is calculated again from energization.
ƹ
&ORFNWLPHUFDQ¶WEHPHPRUL]HG
4. Special Function
(1) Health function (for the model with health function)
'XULQJRSHUDWLRQRIWKH,'8IDQPRWRUSUHVVKHDOWKEXWWRQRQWKHUHPRWHFRQWUROOHUWRVWDUWKHDOWKIXQFWLRQ,IWKHUHLVQRWKHDOWKEXWWRQRQ
WKHUHPRWHFRQWUROOHUWKHXQLWGHIDXOWVKHDOWKIXQFWLRQ21
(2) I Feel function (for all models, but it needs the remote controller which can set this function)
:KHQ,)((/FRPPDQGLVUHFHLYHGWKHFRQWUROOHUZLOORSHUDWHDFFRUGLQJWRWKHDPELHQWWHPSHUDWXUHVHQWE\WKHUHPRWHFRQWUROOHU)RU
GHIURVWLQJDQGFROGDLUSUHYHQWLRQWKHXQLWRSHUDWHVDFFRUGLQJWRWKHDPELHQWWHPSHUDWXUHVHQVHGE\WKHDLUFRQGLWLRQHU7KHUHPRWH
FRQWUROOHUZLOOUHJXODUO\VHQGDPELHQWWHPSHUDWXUHGDWDWRWKHFRQWUROOHU:KHQWKHGDWDKDVQRWEHHQUHFHLYHGIRUDORQJWLPHWKHXQLW
ZLOORSHUDWHDFFRUGLQJWRWKHWHPSHUDWXUHVHQVHGE\WKHDLUFRQGLWLRQHU,I,)((/IXQFWLRQLVQRWVHWWKHDPELHQWWHPSHUDWXUHZLOOEHWKDW
VHQVHGE\WKHDLUFRQGLWLRQHU
F1 ,QGRRUDPELHQWWHPSHUDWXUHVHQVRULVRSHQVKRUWFLUFXLWHG
F2 ,QGRRUHYDSRUDWRUWHPSHUDWXUHVHQVRULVRSHQVKRUWFLUFXLWHG
F3 2XWGRRUDPELHQWWHPSHUDWXUHVHQVRULVRSHQVKRUWFLUFXLWHG
F4 2XWGRRUFRQGHQVHUWHPSHUDWXUHVHQVRULVRSHQVKRUWFLUFXLWHG
E1 +LJKSUHVVXUHSURWHFWLRQ
E3 Low pressure protection of compressor
E4 +LJKGLVFKDUJHWHPSHUDWXUHSURWHFWLRQRIFRPSUHVVRU
E5 Overcurrent protection
E6 Communication malfunction