27
Installation and Maintenance
Service Manual
Note: Please refer to service manual for the troubleshooting procedure for outdoor unit.
Recovery refrigerant mode operation status Fo blink once  blink once 
X-fan operation status
ON for 0.5s 
and OFF for 
10s
Defrosting or oil return in heating operation status
OFF for 0.5s 
and ON for 
10s
Startup failure
It can be displayed 
through remote 
controller within 200s 
and displayed directly 
after 200s
Lc blink 11 times
Compressor exhaust high temperature protection E4 blink 4 times
Anti-high temperature protection E8 blink 8 times
AC over-current protection E5 blink 5 times
Over compressor phase current protection P5 blink 15 times
Compressor loss step protection H7 blink 7 times
Compressor loss of phase protection Ld
IPM protection  H5 blink 5 times
Low PN voltage protection PL blink 21 times
Over voltage protection for PN PH blink 11 times
PFC protection HC blink 6 times
4-way valve reversal abnormal U7 blink 20 times