Super Free Match 
 Service Manual 
 
    PRODUCT 
19 
4.2.4 Floor ceiling type 
Model Heat pump 
GTH(09)BA-K3
DNA1A/I 
GTH(12)BA-K3
DNA1A/I 
GTH(18)BA-K3
DNA1A/I 
GTH(24)BA-K3
DNA1A/I 
Cooling KW  2.50 3.50 5.00 7.10 
Capacity 
Heating KW  2.80 3.85 5.50 8.00 
Power supply  V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 
Motor power input  kW  0.055  0.055  0.11  0.11 
m3/h  650 650 950 1250 
Air flow volume 
CFM 382.5  382.5  559  736 
Sound pressure level 
(H/M/L) 
dB(A)  40/38/36 40/38/36 45/42/40 48/46/44 
Output kW  0.015  0.015  0.02  0.05 
Fan motor 
Running 
current 
A 0.3  0.3  0.5  0.5 
Gas inch 3/8″(Φ9.52mm) 3/8″(Φ9.52mm) 1/2″(Φ12.7mm) 5/8″(Φ15.9mm)
Liquid inch 1/4″(Φ6.35mm) 1/4″(Φ6.35mm) 1/4″(Φ6.35mm) 3/8″(Φ9.52mm)
Connecting 
pipe 
Connection method  Flare Connection Flare Connection Flare Connection Flare Connection
External 
dia. 
mm  Φ17  Φ17  Φ17  Φ17 
Drain pipe 
Thickness mm 1.75 1.75 1.75 1.75 
Outline 
dimension 
W×D×H mm 1220×700×225 1220×700×225 1220×700×225 1220×700×225 
Package 
dimension 
W×D×H mm 1343×823×315 1343×823×315 1343×823×315 1343×823×315 
Net Weight/Gross weight  kg  40/50 40/50 40/50 45/54 
20'GP 66  66  66  66 
40' GP  132 132 132 132 
Loading quantity 
40' HQ  132 132 132 132 
 
Notes: 
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27℃
DB, 19℃WB. Outdoor Temperature is 35℃DB. The rated heating capacity data is measured under the following 
work condition: Indoor Temperature is 20℃DB. Outdoor Temperature is 7℃DB, 6℃WB. 
b. The data will change with the change of products. Refer to those parameters listed on nameplate. 
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.