Service Manual
MODEL:
(Refrigerant R410A)
GWC09KF-K3DNA5A GWC12KF-K3DNA5A
GWH09KF-K3DNA5A GWH12KF-K3DNA5A
GWH09KF-K3DNA6A GWH12KF-K3DNA6A
GWH09KF-K3DNB1A GWH12KF-K3DNB1A

Questions and Answers

  • A
    Alexandria HuberAug 14, 2025
    Why is my Gree Air Conditioner cooling/heating efficiency not good?
    • E
      Elizabeth KingAug 14, 2025
      Check if the temperature setting is appropriate, inlet and outlet vents are unobstructed, the filter is clean, windows and doors are closed, the fan speed is not set to low, and there are no heat sources in the room.
  • D
    Dave JohnsonAug 17, 2025
    Why is the wireless remote control not working for my Gree Air Conditioner?
    • S
      Sydney CrawfordAug 17, 2025
      If the unit is interfered with by abnormal or frequent function switchovers, unplug and reinsert the power plug. Also, ensure the remote is within range and not obstructed. Check the remote's battery voltage and replace the batteries if needed. If the remote is damaged, it may need replacement.
  • D
    David VincentAug 21, 2025
    Why is there water leakage in my Gree GWH09KF-K3DNA5A outdoor unit?
    • M
      Melanie WareAug 21, 2025
      This can happen because the pipe and connection of the pipe would be condensed due to the water cooled down when the unit is running in COOL mode. Also, when the unit is running in Auto Defrosting mode the ice thawed and flowed out. Finally, when the unit is running in HEAT mode, the water adhered on the heat exchanger dripped off.
  • M
    Monique PerryAug 25, 2025
    Why is my Gree Air Conditioner compressor not turning on after turning it off for 3 minutes?
    • P
      Paul MartinezAug 25, 2025
      The Gree Air Conditioner is designed to prohibit turning on the compressor for 3 minutes after it has been turned off.
  • P
    Paul DouglasAug 27, 2025
    How to fix Gree GWH09KF-K3DNA5A Air Conditioner not operating immediately after restarting?
    • P
      peter60Aug 28, 2025
      After the air conditioner is stopped, it will not operate for approximately 3 minutes to protect itself.
  • L
    Lawrence Hayes Jr.Aug 31, 2025
    Why does my Gree Air Conditioner indoor unit not deliver air?
    • D
      Dana DrakeAug 31, 2025
      This can happen for a few reasons. When the temperature of the indoor heat exchanger is very low, the unit will stop delivering air to prevent cool air. Also, when the outdoor temperature is low or the humidity is high, frost can form on the outdoor heat exchanger, causing the unit to automatically defrost, during which the indoor unit will stop blowing air for 3-12 minutes. In dehumidifying mode, the indoor fan may stop to prevent condensed water from vaporizing again and to restrain temperature rising.
  • Q
    qguerreroSep 3, 2025
    What to do if there's a strange smell coming from my Gree GWH09KF-K3DNA5A?
    • A
      Austin BarkerSep 3, 2025
      The smell may be accumulated in the ambient. Clean the filter. If the problem persists, the air conditioner needs cleaning, so contact an authorized maintenance center.
  • H
    Heather SmallSep 6, 2025
    Why is there moisture on the air outlet vent of my Gree Air Conditioner?
    • D
      Duane AndersonSep 6, 2025
      If the unit is running under high humidity for a long time, moisture will condense on the air outlet grill and drip off.
  • N
    nicolekochSep 10, 2025
    What to do if my Gree Air Conditioner unit cannot run?
    • B
      bethanymccarthySep 10, 2025
      Check if the power has been shut down, the power plug is loose, the circuit protection device has tripped, the voltage is too high or low (tested by professionals), and the TIMER is correctly set.

Gree GWH09KF-K3DNA5A Specifications

General IconGeneral
TypeSplit Air Conditioner
Cooling Capacity9000 BTU/h
Heating Capacity9500 BTU/h
Energy Efficiency Ratio (EER)3.21
RefrigerantR410A
Power Supply220-240V, 50Hz
Coefficient of Performance (COP)3.61
Indoor Unit Weight9 kg
Outdoor Unit Weight27 kg
Outdoor Unit Noise Level50 dB(A)