,QVWDOODWLRQDQG0DLQWHQDQFH
6HUYLFH0DQXDO
Remove screws fixing the electric box assy; loosen
the wire bundle and unplug the wiring terminals.
Then lift the electric box to remove it.
5.Remove axial flow blade
Remove the nut fixing the blade and then
remove the axial flow blade.
Axial flow blade
Steps Procedure
7.Remove motor and motor support
motor support
6.Remove electric box assy
Remove the 4 tapping screws fixing the motor.
Pull out the lead-out wire and remove the
motor. Remove the 2 tapping screws fixing
the motor support. Lift motor support to re-
move it.
motor
electric box assy