41
Technical Information
Service Manual
● Outdoor Unit
5
6
7
814 159
10
11
12
13
12 34
No. Name No. Name
1 Input of transformer 9 Terminal for outdoor pipe temp sensor
2 Terminal for 4-way valve 10 Terminal for communication wire
3 Terminal for outdoor fan 11 Protective tube
4 Terminal for compressor 12 Terminal for neutral wire
5 Output of transformer 13 Terminal for live wire
6 Terminal for high pressure protection 14
Current mutual-inductor(only for the model
with this function)
7 Terminal for low pressure protection 15
Needle stand of discharge temp sensor
(only for the model with this function)
8 Terminal for outdoor ambient temp sensor
GWH36QE-K3NNB4A/O