113
Installation and Maintenance
Step Procedure
13. Remove electronic expansion valve
Remove the terminals of the electric expand valve
fitting and rotate to remove the electric expand valve
tting
.
Unsolder the welding joint connecting the electronic
expansion Valve and then remove the electronic
expansion valve.
14. Remove clapboard assy
Remove the screws xing the clapboard assy and then
remove the clapboard assy.
15. Remove compressor
Remove the 3 foot nuts on the compressor and then
remove the compressor.
welding joint
electric expansion
valve sub-Assy
electric expand
valve tting
clapboard assy
compressor
nut