37
Installation and Maintenance
Service Manual
Possible Causes 'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV 7URXEOHVKRRWLQJ
Set temperature is improper 2EVHUYHWKHVHWWHPSHUDWXUHRQUHPRWHFRQWUROOHU$GMXVWWKHVHWWHPSHUDWXUH
5RWDWLRQVSHHGRIWKH,'8IDQ
motor is set too low
Small wind blow 6HWWKHIDQVSHHGDWKLJKRUPHGLXP
)LOWHURILQGRRUXQLWLVEORFNHG &KHFNWKH¿OWHUWRVHHLWVEORFNHG &OHDQWKH¿OWHU
Installation position for indoor unit
and outdoor unit is improper
&KHFNZKHWKHUWKHLQVWDOODWLRQSRVWLRQLVSURSHU
according to installation requirement for air
conditioner
$GMXVWWKHLQVWDOODWLRQSRVLWLRQDQGLQVWDOOWKH
rainproof and sunproof for outdoor unit
5HIULJHUDQWLVOHDNLQJ
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJFRROLQJLV
KLJKHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJKHDWLQJLV
ORZHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
8QLWVSUHVVXUHLVPXFKORZHUWKDQUHJXODWHG
range
)LQGRXWWKHOHDNDJHFDXVHVDQGGHDOZLWKLW
Add refrigerant.
Malfunction of 4-way valve EORZFROGZLQGGXULQJKHDWLQJ 5HSODFHWKHZD\YDOYH
Malfunction of capillary
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJFRROLQJLV
KLJKHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJKHDWLQJLV
ORZHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
8QLWWSUHVVXUHLVPXFKORZHUWKDQUHJXODWHG
UDQJH,IUHIULJHUDQWLVQ¶WOHDNLQJSDUWRIFDSLOODU\
LVEORFNHG
5HSODFHWKHFDSLOODU\
Flow volume of valve is
LQVXI¿FLHQW
7KHSUHVVXUHRIYDOYHVLVPXFKORZHUWKDQWKDW
VWDWHGLQWKHVSHFL¿FDWLRQ
2SHQWKHYDOYHFRPSOHWHO\
0DOIXQFWLRQRIKRUL]RQWDOORXYHU Horizontal louver can’t swing
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
details
0DOIXQFWLRQRIWKH,'8IDQPRWRU 7KH,'8IDQPRWRUFDQ¶WRSHUDWH
5HIHUWRWURXEOHVKRRWLQJIRU+IRUPDLQWHQDQFH
PHWKRGLQGHWDLOV
0DOIXQFWLRQRIWKH2'8IDQPRWRU7KH2'8IDQPRWRUFDQWRSHUDWH
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
details
Malfunction of compressor Compressor can't operate
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
details
9.3 Maintenance Method for Normal Malfunction
1. Air Conditioner Can't be Started Up
2. Poor Cooling (Heating) for Air Conditioner
3. Horizontal Louver Can't Swing
Possible Causes 'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV 7URXEOHVKRRWLQJ
No power supply, or poor
connection for power plug
$IWHUHQHUJL]DWLRQRSHUDWLRQLQGLFDWRULVQ¶WEULJKW
DQGWKHEX]]HUFDQWJLYHRXWVRXQG
&RQ¿UPZKHWKHULWVGXHWRSRZHUIDLOXUH,I\HV
ZDLWIRUSRZHUUHFRYHU\,IQRWFKHFNSRZHU
VXSSO\FLUFXLWDQGPDNHVXUHWKHSRZHUSOXJLV
connected well.
Wrong wire connection between
indoor unit and outdoor unit,
or poor connection for wiring
terminals
Under normal power supply circumstances,
RSHUDWLRQLQGLFDWRULVQWEULJKWDIWHUHQHUJL]DWLRQ
&KHFNWKHFLUFXLWDFFRUGLQJWRFLUFXLWGLDJUDP
DQGFRQQHFWZLUHVFRUUHFWO\0DNHVXUHDOO
ZLULQJWHUPLQDOVDUHFRQQHFWHG¿UPO\
(OHFWULFOHDNDJHIRUDLUFRQGLWLRQHU
$IWHUHQHUJL]DWLRQURRPFLUFXLWEUHDNHUWULSVRIIDW
once
0DNHVXUHWKHDLUFRQGLWLRQHULVJURXQGHG
reliably
0DNHVXUHZLUHVRIDLUFRQGLWLRQHULVFRQQHFWHG
correctly
&KHFNWKHZLULQJLQVLGHDLUFRQGLWLRQHU&KHFN
ZKHWKHUWKHLQVXODWLRQOD\HURISRZHUFRUGLV
GDPDJHGLI\HVSODFHWKHSRZHUFRUG
0RGHOVHOHFWLRQIRUDLUVZLWFKLV
improper
$IWHUHQHUJL]DWLRQDLUVZLWFKWULSVRII 6HOHFWSURSHUDLUVZLWFK
Malfunction of remote controller
$IWHUHQHUJL]DWLRQRSHUDWLRQLQGLFDWRULVEULJKW
ZKLOHQRGLVSOD\RQUHPRWHFRQWUROOHURUEXWWRQV
KDYHQRDFWLRQ
Replace batteries for remote controller
Repair or replace remote controller
Possible Causes 'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV 7URXEOHVKRRWLQJ
Wrong wire connection, or poor
connection
&KHFNWKHZLULQJVWDWXVDFFRUGLQJWRFLUFXLW
diagram
Connect wires according to wiring diagram to
PDNHVXUHDOOZLULQJWHUPLQDOVDUHFRQQHFWHG
¿UPO\
Stepping motor is damaged Stepping motor can't operate Repair or replace stepping motor
Main board is damaged
2WKHUVDUHDOOQRUPDOZKLOHKRUL]RQWDOORXYHU
can't operate
5HSODFHWKHPDLQERDUGZLWKWKHVDPHPRGHO

Related product manuals