95
Installation and Maintenance
Service Manual
1
2
6.Remove soundproof sponge and
Since the piping ports on the soundproof sponge are
torn easily, remove the soundproof sponge carefully
7. Remove Isolation sheet
Remove the 3 screws fixing the isolation sheet
and then remove the Isolation sheet.
Isolation sheet
Discharge the refrigerant completely;unsolder
the pipelines connecting the compressor and
the condenser assy,and then remove the 4-way
valve assy.
4-way valv e assy
4-way valv e assy
Connection Pipe
soundproof sponge