c. If the switch is in RUN position , the machine will run according to the remote signal.
d. If the switch is in STOP position, the machine will stop.
5. SLEEP mode.
a. In cooling or dehumidifying mode, 1 hour after you set the sleep timer ,T
set
will add 1
automatically, another 1 hour, another 1 will be added.
b. In heating mode, 1 hour after you set the sleep timer, T
set
will lower 1 automatically, another
1 hour, another 1
will be lowered .
6.Automatic fan speed .
a. In cooling mode, if T
indoor
T
set
+ 5
high speed
T
set
+3 T
indoor
T
set
+5 middle speed
T
indoor
T
set
+ 1 low speed
b. In heating mode, if T
indoor
T
set
- 5
high speed
T
indoor
<T
set
-3 middle speed
T
indoor
T
set
-1 low speed
c. In dehumidifying mode T
indoor
T
set
+5
high speed
T
indoor
T
set
+2
low speed